ATLANTA, GA —
OSHA Inspection: ARM CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARM CONSTRUCTION in 3640 RIVERS CALL BOULEVARD, ATLANTA, GA 30379 (NAICS 238130). OSHA activity number 337206015.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARM CONSTRUCTION
- Site address
- 3640 RIVERS CALL BOULEVARD
- City
- ATLANTA
- State
- GA
- ZIP
- 30379
- Mailing
- 213 MORNING GLORY RIDGE, CANTON, GA 30115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.304 D
- Issued
- Jan 28, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe: a) Covered patio. An employee was using a seven and one quarter inch circular saw to cut plywood sheathing to size for installation. The blade guard of the saw had been blocked in the fully open position exposing the employee to amputation hazards.
Recent events (1)
- — Z (S) $2800
1926.501 B13
- Issued
- Jan 28, 2013
- Abate by
- Feb 1, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Patio roof of residence. An employee, who was not wearing a personal fall arrest system while installing sheathing from the unprotected 5 in 12 pitched patio roof was exposed to fall hazards of 12-feet 2-inches.
Recent events (1)
- — Z (S) $2800
1926.1053 B13
- Issued
- Jan 28, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: a) Covered patio of residence. An employee installing sheathing from a 6-foot fiberglass double sided self-supporting ladder was standing on the top step of each side of the ladder while straddling the top of the ladder.
Recent events (1)
- — Z (S) $2000
1926.405 G02 IV
- Issued
- Jan 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Covered patio of residence. An employee was using a seven and one quarter inch circular saw to cut plywood sheathing to size for installation. The flexible cord providing power to a circular saw was damaged allowing pull to be directly transmitted to the joints and/or terminal screws of the plug
Recent events (1)
- — Z (O) $0
1926.1060 A
- Issued
- Jan 28, 2013
- Abate by
- Feb 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) Covered patio of residence. An employee installing sheathing from a 6-foot fiberglass double sided self-supporting ladder had not been provided ladder safety training by the employer.
Recent events (1)
- — Z (O) $0
More inspections at ARM Construction
View ARM Construction's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337206015.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.