OSHA Inspection: C & J INDUSTRIES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C & J INDUSTRIES in 760 WATER STREET, MEADVILLE, PA 16335 (NAICS 326199). OSHA activity number 337216410.

Watch C & J Industries — free Get an email when a new federal OSHA severe-injury report for C & J Industries is published. One employer, no account, unsubscribe in one click.
Establishment
C & J INDUSTRIES
Site address
760 WATER STREET
City
MEADVILLE
State
PA
ZIP
16335
Mailing
760 WATER STREET, MEADVILLE, PA 16335
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
280
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $3000.00 Reduced
29 CFR 1910.147(c)(4)(ii):     Procedures did not clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utllized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h):      A.)  C & J Industries - On or about 11/1/12, the company's lockout/tagout (control of Hazardous Energy) procedures lacked items including, but not limited to, specific explaination of how to relieve stored energy,specific procedural steps for locking out and re-energizing the equipment, step for verifying de-energization, steps for notifying affected employees, and the types and magnitudes of energy for each piece of machinery.  Employees perform servicing and maintenance on machinery including, but not limited to, Toshiba Press #75.        ABATEMENT CERTIFICATION REQUIRED:  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4000

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:        A.)  C & J Industries, throughout facility - On or about 11/1/12, an annual periodic inspection of the lockout/tagout procedures had not been conducted.  Personnel perform servicing and maintenance work on machines and equipment including, but not limited to, Toshiba Press #75.  The periodic inspection did not cover all authorized employees and did not review an actual lockout in progress.