Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DONJON SHIPBUILDING AND REPAIR LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DONJON SHIPBUILDING AND REPAIR LLC in 220 EAST BAYFRONT PARKWAY, ERIE, PA 16507 (NAICS 336611). OSHA activity number 337223424.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Donjon Shipbuilding and Repair LLC — free Get an email when a new federal OSHA severe-injury report for Donjon Shipbuilding and Repair LLC is published. One employer, no account, unsubscribe in one click.
Site address
220 EAST BAYFRONT PARKWAY
City
ERIE
State
PA
ZIP
16507
Mailing
220 EAST BAYFRONT PARKWAY, ERIE, PA 16507
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
131
Ownership type
A

7 citations on file for this inspection.

1910.134 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
Jun 4, 2013
Penalty
Initial $2,700 · Current $1,400 Reduced
29 CFR 1910.134(f)(2):  The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter:    a.) DonJon Shipbuilding & Repair, LLC, 220 East Bayfront Parkway, Erie, PA, on or about November 2nd, 2012, and times prior thereto:  Company employees were not provided with fit tests prior to use of 3M brand half mask air purifying respirators, and annually thereafter.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2700

1910.134 G01 I A

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    a.) DonJon Shipbuilding & Repair, LLC, 220 East Bayfront Parkway, Erie, PA, on or about November 2nd, 2012, and times prior thereto:  Company employees who were using 3M brand half mask air purifying respirators were not clean shaven.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D03 III B 2

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:    a.) DonJon Shipbuilding & Repair, LLC, 220 East Bayfront Parkway, Erie, PA, on or about October 31st, 2012, and times prior thereto:  Company employees routinely use 3M brand half mask air purifying respirators with organic vapor cartridges and particulate filters.  A change out schedule for replacing the cartridges had not been developed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 I01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $4,500 · Current $2,300 Reduced
29 CFR 1910.134(i)(1)(ii):  Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989:    a.)DonJon Shipbuilding & Repair, LLC, 220 East Bayfront Parkway, Erie, PA-Blast Shack-Northwest corner of the facility-on or about January 28th, 2013, and times prior thereto:  Company employees were utilizing supplied breathing air from an oil-lubricated Quincy (QSI-750 Serial # BB1008160130) air compressor through a supplied air respirator, with an Allegro 3 stage inline filter panel system.  The company did not ensure that the compressed breathing air, supplied to company employees, met at least the requirements for Grade D breathing air.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $4500

1910.134 I05 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $4,500 · Current $2,300 Reduced
29 CFR 1910.134(i)(5)(iii): The compressor's sorbent bed and filters were not maintained and replaced or refurbished periodically as instructed by the manufacturer:    a.) DonJon Shipbuilding & Repair, LLC, 220 East Bayfront Parkway, Erie, PA-Blast Shack-Northwest corner of the facility-on or about January 28th, 2013, the Allegro Industries three stage filter system (#96424) installed in a compressor line, used to supply breathing air to supplied air respirators, were not replaced as directed by the manufacturer.  The manufacturers instructions stated that the first stage filter must be changed every 200 running hours, the 2nd and 3rd stage filter must be changed every 400 running hours.  The filters utilized to filter supplied breathing air to employees were not maintained and replaced periodically following the manufacturers instructions.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $4500

1910.134 I05 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(i)(5)(iv):  The employer did not ensure that the person authorized to perform the necessary sorbent bed and filter changes filled out a tag indicating by the signature and date that maintenance changes were performed:    a.) DonJon Shipbuilding & Repair, LLC, 220 East Bayfront Parkway, Erie, PA-Blast Shack-Northwest corner of the facility-on or about January 28th, 2013, and times prior thereto: Company employees were utilizing supplied breathing air from an oil-lubricated Quincy (QSI-750 Serial # BB1008160130) air compressor through a supplied air respirator with an Allegro 3 stage inline filter panel system (#96424).  The companys Allegro filter system did not have a tag containing the most recent change date and the signature of the person authorized by the employer to perform the change.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 I07

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(i)(7):  Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:    a.)DonJon Shipbuilding & Repair, LLC, 220 East Bayfront Parkway, Erie, PA-Blast Shack-Northwest corner of the facility-on or about January 28th, 2013, and times prior thereto:  Company employees were utilizing supplied breathing air from an oil-lubricated Quincy (QSI-750 Serial # BB1008160130) air compressor through a supplied air respirator with an Allegro 3 stage inline filter panel system(#96424).  The company did not monitor for Carbon Monoxide in the supplied breathing air used by company employees who were performing blasting/painting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Donjon Shipbuilding and Repair LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337223424.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.