HONOLULU, HI —
OSHA Inspection: MARTIN & MACARTHUR ENTERPRISES, LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARTIN & MACARTHUR ENTERPRISES, LTD. in 1815 KAHAI ST., HONOLULU, HI 96819 (NAICS 337122). OSHA activity number 337231625.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARTIN & MACARTHUR ENTERPRISES, LTD.
- Site address
- 1815 KAHAI ST.
- City
- HONOLULU
- State
- HI
- ZIP
- 96819
- Mailing
- 1815 KAHAI ST., HONOLULU, HI 96819
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337122
- Employees
- 96
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.22 A01
- Issued
- Nov 21, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $2,975 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a) On or about November 6, 2012, the dust accumulation inside the shop on electrical outlets, duct work, electrical cabinets, and conduit exposed employees to fire and explosion hazards. The employer did not assure work areas such as, but not limited to, Bay 3 was cleaned promptly and to its entirety. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1800
- — Z (S) $2975
1910.307 C02 I
- Issued
- Nov 21, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present: a) On or about November 6, 2012, the employer did not assure that electrical installations such as, but not limited to, receptacles, electrical cabinets and disconnects, in the Bay 3 woodworking area were Class II rated. Employees were exposed to fire and explosion hazards from accumulation of wood dust and lack of Class II electrical equipment throughout the shop area. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 F03
- Issued
- Nov 21, 2012
- Penalty
- Initial $1,785 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(f)(3): Sprinklers protecting spraying areas were not kept as free from deposits as practical by cleaning daily if necessary: a) Employees working in the spray booth were exposed to fire hazards in that the employer did not assure the sprinkler heads were kept free from overspray accumulation. No additional abatement information is needed for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $1785
1910.107 G02
- Issued
- Nov 21, 2012
- Penalty
- Initial $1,785 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a) Employees working in the spray booth were exposed to fire hazards in that the employer did not assure that all areas of the spray booth were kept free from overspray accumulations. Overspray accumulations were present in the ventilation area behind the filters. No additional abatement information is needed for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $1785
1910.134 C01
- Issued
- Nov 21, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $1,785 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) The employer did not develop and implement a written respiratory program to protect employees from worksite respiratory hazards. A written program was not developed for employees wearing disposable respirators during wood working and an employee who utilizes a SATA supplied air respirator while performing spray finishing operations in a spray booth. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1200
- — Z (S) $1785
1910.134 I07
- Issued
- Nov 21, 2012
- Penalty
- Initial $1,785 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: a) The employer did not assure that a carbon monoxide alarm was used to monitor carbon monoxide levels in the supplied breathing air for the spray finisher. An Ingersoll Rand oil-lubricated compressor was used to supply breathing air for an employee performing the spray operations. No additional abatement information is needed for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $1785
1910.212 A03 II
- Issued
- Nov 21, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $2,975 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) On or about November 8, 2012, the employer did not assure that employees who operated the Hofer horizontal wood press were protected from crushing and burn injuries. The machine was not guarded to prevent employees from being exposed to the point of operation. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1200
- — Z (S) $2975
1910.303 G01
- Issued
- Nov 21, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) The employer did not assure that access to the electrical panels was maintained with at least three feet clear space. The area in front of the electrical equipment located in the Bay 2 and Bay 3 was blocked by fixtures and/or wood supplies, hindering an employee's ability to access the equipment. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Martin & Macarthur Enterprises, LTD.
View Martin & Macarthur Enterprises, LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 337122)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337231625.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.