OSHA Inspection: WEILAND CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WEILAND CONSTRUCTION in 111 14TH ST., TOLEDO, OH 43604 (NAICS 238160). OSHA activity number 337255822.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Weiland Construction — free Get an email when a new federal OSHA severe-injury report for Weiland Construction is published. One employer, no account, unsubscribe in one click.
Site address
111 14TH ST.
City
TOLEDO
State
OH
ZIP
43604
Mailing
965 N. CURTICE, OREGON, OH 43616
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.502 F01

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 29, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area.    a) Weiland Construction on or about November 22, 2012, at the address of 111 14th St. Toledo, OH: The employer failed to ensure a warning line system was installed around the entire perimeter of the roof deck (work area). Employees working in the area of unmarked/unguarded edges were exposed to falls of up to 17 ft. to the ground below.
Recent events (1)
  • — Z (S) $2000

1926.502 F02 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 29, 2012
Abate by
Dec 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(2)(iv): The rope, wire, or chain did not have a minimum tensile strength of 500 pounds (2.22 kN), and after being attached to the stanchions, capable of supporting, without breaking, the loads applied to the stanchions as prescribed in paragraph (f)(2)(iii) of this section.    a)  Weiland Construction on or about November 22, 2012, at the address of 111 14th St. Toledo, OH: The employer failed to ensure the material used as a warning line had a tensile strength of at least 500 lb. Caution Tape utilized as the warning line does not provide adequate notice of fall hazards while employees work in proximity to the unguarded edge. Employees working in the area of unguarded and/or insufficiently marked edges were exposed to falls of up to 17 ft. to the ground below.
Recent events (1)
  • — Z (S) $0