OSHA Inspection: FIBER GLASS SYSTEMS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FIBER GLASS SYSTEMS INC. in 2425 SW 36TH STREET, SAN ANTONIO, TX 78237 (NAICS 326122). OSHA activity number 337258016.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fiber Glass Systems INC. — free Get an email when a new federal OSHA severe-injury report for Fiber Glass Systems INC. is published. One employer, no account, unsubscribe in one click.
Site address
2425 SW 36TH STREET
City
SAN ANTONIO
State
TX
ZIP
78237
Mailing
2425 SW 36TH STREET, SAN ANTONIO, TX 78237
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326122
Employees
150
Ownership type
A

8 citations on file for this inspection.

1910.22 D01

Other-than-serious 1 instance 6 exposed
Issued
Dec 20, 2012
Penalty
Initial $3,400 · Current $2,040 Reduced
29 CFR 1910.22(d)(1):  On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building:    Parts Warehouse, On or about 11/7/12 and at times prior thereto employees were exposed to being struck by a collapsing ceiling from a series of cardboard boxes containing unknown material stored on the roof while processing orders in the warehouse.
Recent events (2)
  • — I (O) $2040
  • — Z (S) $3400

1910.157 C01

Other-than-serious 2 instances 18 exposed
Issued
Dec 20, 2012
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a)  Parts warehouse, On or about 11/7/12 employees were exposed to in case of an emergency, not being able to respond to a fire quickly, from boxes and containers that were placed around the fire extinguisher.     b)  Building 8, On or about 11/7/12 employees were exposed to in case of an emergency, not being able to respond to a fire quickly, from a table that was placed in front of and blocking a fire extinguisher.
Recent events (2)
  • — I (O) $1530
  • — Z (S) $2550

1910.212 A01

Serious Gravity 5 1 instance 15 exposed
Issued
Dec 20, 2012
Abate by
Jan 5, 2013
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Building 8, Wilton Drill Press: On or about 11/7/12 and at times prior thereto employee(s) are exposed to being struck by an unguarded rotating chuck from while using a drill press to drill taps onto brackets measuring approximately 1" x 1/4" x 6".
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.212 B

Serious Gravity 5 1 instance 15 exposed
Issued
Dec 20, 2012
Penalty
Initial $3,400 · Current $2,040 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:            Building 8, Drill Press labeled as manufactured for Wilton U.S.A. Machinery Division: On or about 11/7/12 and at times prior thereto employee(s) are exposed to being struck by an unguarded rotating chuck from while using a drill press to drill taps onto brackets measuring approximately 1" x 1/4" x 6".
Recent events (2)
  • — I (S) $2040
  • — Z (S) $3400

1910.215 A04

Serious Gravity 5 1 instance 8 exposed
Issued
Dec 20, 2012
Abate by
Dec 27, 2012
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    Engineering Fabrication Area, Sears Craftsman 8" Bench Grinder Model 319190631: On or about 12/27/10 and at times prior thereto employee(s) were exposed to a struck by hazard, when sharpening a knife to open boxes with, from a work rest being approximately 1/2 inch from the abrasive wheel.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.242 B

Serious Gravity 5 1 instance 16 exposed
Issued
Dec 20, 2012
Abate by
Dec 31, 2012
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    Fittings Department, On or about 11/7/12 and at times prior thereto, employee(s) routinely use compress air at pressures greater than 30 p.s.i., while cleaning their work areas.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.304 G02 III

Other-than-serious 1 instance 15 exposed
Issued
Dec 20, 2012
Penalty
Initial $4,250 · Current $2,550 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    Building 8, Airmaster Pedestal Mounted Fan Model: LC30AP, S/N: E65152:  On or about 11/7/12 employee(s) were exposed to an electrical shock of 120 Volts from using a fan, that had the outer protective sheathing pulled back on the end that connected to the fan motor, to help ventilate fumes while painting yellow cages/barriers.
Recent events (2)
  • — I (O) $2550
  • — Z (S) $4250

1910.304 G05

Serious Gravity 5 1 instance 15 exposed
Issued
Dec 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    Building 8, Airmaster Pedestal Mounted Fan Model: LC30AP, S/N: E65152:  On or about 11/7/12 employee(s) were exposed to an electrical shock of 120 Volts while using a fan missing a grounding plug to help ventilate fumes while painting yellow cages/barriers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0