OSHA Inspection: ROYAL ELECTRIC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ROYAL ELECTRIC in 2020 JACKSON PIKE, COLUMBUS, OH 43223 (NAICS 238210). OSHA activity number 337270631.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Royal Electric — free Get an email when a new federal OSHA severe-injury report for Royal Electric is published. One employer, no account, unsubscribe in one click.
Establishment
ROYAL ELECTRIC
Site address
2020 JACKSON PIKE
City
COLUMBUS
State
OH
ZIP
43223
Mailing
1250 MEMORY LANE N., COLUMBUS, OH 43209
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
25
Ownership type
A

3 citations on file for this inspection.

1926.405 B01

Deleted Serious Gravity 5 7 instances 4 exposed
Issued
Dec 6, 2012
Abate by
Dec 26, 2012
Penalty
Initial $1,360 · Current $0 Reduced
29 CFR 1926.405(b)(1):     Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.    a.     In the compressor area, there was a 480 volt energized electrical panel which had an unused opening in the  panel thereby exposing employees to a contact hazard.    b.      On the east side of Shaft 1, there was a 2 inch unused opening in the bottom of the energized 120/208 electrical panel thereby exposing employees to a contact hazard.    c.       In the bottom of Shaft 2, there was an unused opening in the bottom of the 277/480 energized electrical panel thereby exposing employees to a contact hazard.    d.       On the south side of Shaft 6, there was an unused opening in the bottom of the energized 480 volt electrical panel thereby exposing employees to a contact hazard.     e.        On the east side of Shaft 6, their was an unused opening in the bottom of the energized electrical outlet box, thereby exposing employees to a contact hazard.    f.        On the north side of Shaft 6, there was an unused opening in the bottom of the energized 480 volt electrical panel, thereby exposing employees to a contact hazard.    g.        On the Neil Street location where tunneling was being performed, there was a unused opening in the electrical outlet box thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1360

1926.416 E01

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Dec 6, 2012
Abate by
Dec 26, 2012
Penalty
Initial $1,020 · Current $0 Reduced
29 CFR 1926.416(e)(1):     Worn or frayed electric cords or cables shall not be used.    a.     On the Neil Road where electrical equipment was used to provide power for portable tools and lighting, the electrical cord to the outlet was worn and pulled from the electrical box thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1020

1926.432 B

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Dec 6, 2012
Abate by
Dec 26, 2012
Penalty
Initial $1,360 · Current $0 Reduced
29 CFR 1926.432(b):     Protection against corrosion. Metal raceways, cable armor, boxes, cable sheathing, cabinets, elbows, couplings, fittings, supports, and support hardware shall be of materials appropriate for the environment in which they are to be installed.      a.     In Shaft 2 where electrical equipment was set up to provide power to equipment, tools and other lighting, protection was not provided over the electrical equipment in the shaft to keep water from getting inside the electrical equipment and causing corrosion on the electrical equipment thereby exposing employees to a contact hazard.