Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TESECON, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TESECON, INC. in 12650 HWY 43 N, AXIS, AL 36505 (NAICS 236210). OSHA activity number 337272850.

Watch Tesecon, INC. — free Get an email when a new federal OSHA severe-injury report for Tesecon, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TESECON, INC.
Site address
12650 HWY 43 N
City
AXIS
State
AL
ZIP
36505
Mailing
660 LOEFFLER ST., MOBILE, AL 36670
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.1101 F03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1500.00 Reduced

Hazardous substances 9954

29 CFR 1926.1101(f)(3)(i): The employer failed to conduct daily monitoring that was representative of the exposure of each employee assigned to work in regulated areas and performing Class I or II work.    On or about October 1, 2012 and during the duration of the job, the employer failed to monitor for asbestos during work done on the removal of transite panels containing chrysotile asbestos from the Old CBU roof at the AMVAC Chemical Companys facility after it became evident that some of the tiles were breaking.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2380

1926.1101 F02 I

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9954

29 CFR 1926.1101(f)(2)(i): The employer failed to ensure that the exposure assessment was conducted in time to comply with requirements which are triggered by the exposure data or the lack of a negative exposure assessment:    On or about October 1, 2012 the employer failed to do initial monitoring for asbestos before work began on the removal of transite panels containing chrysotile asbestos from the Old CBU roof at the AMVAC Chemical Companys facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337272850.