Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: Y.HATA & CO., LIMITED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of Y.HATA & CO., LIMITED in 285 SAND ISLAND ACCESS ROAD, HONOLULU, HI 96819 (NAICS 424410). OSHA activity number 337305429.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Y.Hata & CO., Limited — free Get an email when a new federal OSHA severe-injury report for Y.Hata & CO., Limited is published. One employer, no account, unsubscribe in one click.
Site address
285 SAND ISLAND ACCESS ROAD
City
HONOLULU
State
HI
ZIP
96819
Mailing
285 SAND ISLAND ACCESS ROAD, HONOLULU, HI 96819
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424410
Employees
195
Ownership type
A

6 citations on file for this inspection.

1910.147 F03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2012
Abate by
Dec 13, 2012
Penalty
Initial $3,600 · Current $3,250 Reduced
29 CFR 1910.147(f)(3)(i):     A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, ;   a) On or about 11/8/12 in the dock area; two employees are involved in cleaning ( service and maintenance ) of the loading dock pit areas for Dock 1-#12, however only one lock is used for energy control during this activity.       Abatement Certification
Recent events (2)
  • — I (S) $3250
  • — Z (S) $3600

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2012
Abate by
Dec 21, 2012
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A):     Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation area;   a) On or about 11/8/12 in the dock area; with the controls locked out, an employee uses vacuum cleaner to clean the pit area inside the mechanical loading docks # 1- 12 and has not been trained as an authorized employee.    Abatement Certification
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

1910.303 B07 IV

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 16, 2012
Abate by
Dec 6, 2012
Penalty
Initial $3,600 · Current $3,250 Reduced
29 CFR 1910.303(b)(7)(iv):     There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.   a) On or about 11/8/12 in the Maintenance shop; a yellow cord set (extension cord) was found insulation pulled away from the male end and being used to supply power to portable electrical equipment, such as but not limited to, saws, lights, power tools.      b) On or about 11/8/12 in the Janitor area; a red cord set ( extension cord ) was found with insulation pulled away from the female end and being used to supply power to portable electrical equipment, such as but not limited to, wet dry vacuum.        Abatement Certification
Recent events (2)
  • — I (S) $3250
  • — Z (S) $3600

1910.304 G05

Serious 2 instances 2 exposed
Issued
Nov 16, 2012
Abate by
Dec 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):     The paths to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective  a) On or about 11/8/12 in the Maintenance shop; a yellow cord set (extension cord) was found missing the grounding pin and being used to supply power to portable electrical equipment, such as but not limited to, saws, lights, power tools.      b) On or about 11/8/12 in the Janitor area; a red cord set ( extension cord ) was found missing the grounding pin and being used to supply power to portable electrical equipment, such as but not limited to, wet dry vacuum.        Abatement Certification
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C01

Other-than-serious 1 instance 3 exposed
Issued
Nov 16, 2012
Abate by
Dec 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1):     The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  a) On or about 11/8/12 throughout the facility; employer has permit required confined spaces, such as but not limited to, loading dock plate pits, for Docks #1- 12.   Abatement Certification
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Nov 16, 2012
Abate by
Dec 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about 11/8/12 in the dock area; Energy Control Procedure - Specific Equipment for the Hydraulic Dock Plates has never been audited and is used on a least a monthly basis prior to cleaning the dock pits #1 -12.    Abatement Certification
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337305429.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.