Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NOE OMAR ROBLES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NOE OMAR ROBLES in 16610 QUAYSIDE DRIVE, MILTON, GA 30004 (NAICS 238140). OSHA activity number 337307813.

Watch NOE Omar Robles — free Get an email when a new federal OSHA severe-injury report for NOE Omar Robles is published. One employer, no account, unsubscribe in one click.
Establishment
NOE OMAR ROBLES
Site address
16610 QUAYSIDE DRIVE
City
MILTON
State
GA
ZIP
30004
Mailing
920 SOUTH COBB DRIVE LOT 15, MARIETTA, GA 30060
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
15
Ownership type
A

8 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    a) Front of residence 16610 Quayside Drive, Milton, Georgia.The employer did not ensure the use of personal protective equipment for the employees cutting bricks to size with a circular saw or for the employee cutting artificial decorative stone with a masons chop saw.
Recent events (1)
  • — Z (S) $2000

1926.451 B01

Serious Gravity 10 3 instances 4 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)    a) The working platforms of the fabricated frame scaffolding system were not fully planked or decked exposing employees to fall hazards of approximately 15-feet 2-inches, 14-feet 1-inch,  and 13-feet 6-inches.
Recent events (1)
  • — Z (S) $2800

1926.451 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm):    a) Front of residence located at 16610 Quayside Drive Milton, Georgia. Each end of unrestrained scaffold platforms did not extend over the centerline of its support at least 6 inches.
Recent events (1)
  • — Z (S) $2000

1926.451 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilivered end:    a) The front of residence located at 16610 Quayside Drive, Milton, Georgia. Each end of scaffold platforms 10 feet or less in length extended over its support more than 12 inches. The platforms were not installed so that the cantilevered portion of the platform could support employees and/or materials without tipping. Nor was employee access to the cantilevered end of the platforms blocked.
Recent events (1)
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 3 instances 5 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a) Front of residence located at 16610 Quayside Drive, Milton, Georgia. The employees were not protected from falling approximately 15-feet 2-inches, 14-feet 1-inch, or 13-feet 6-inches from the fabricated frame scaffold working platforms to the ground by the use of a guardrail or safety net system or personal fall arrest systems.     b) Front of residence located at 16610 Quayside Drive, Milton, Georgia. The employees were not protected from falling approximately 14-feet 1-inch from the fabricated frame scaffold working platforms to the ground by the use of a guardrail or safety net system or personal fall arrest systems.     c) Front of residence located at 16610 Quayside Drive, Milton, Georgia. The employees were not protected from falling approximately 13-feet 6-inches from the fabricated frame scaffold working platforms to the ground by the use of a guardrail or safety net system or personal fall arrest systems.
Recent events (1)
  • — Z (S) $2800

1926.452 C02

Serious Gravity 10 2 instances 3 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:     a) Front of residence located at 16610 Quayside Drive, Milton, Georgia. Not all of the panels of the fabricated frame scaffold system were braced by cross, horizontal, or diagonal braces to secure vertical members together laterally which would automatically square and align vertical members so that the erected scaffold is plumb, level, and square
Recent events (1)
  • — Z (S) $2800

1926.404 F06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) Front of residence located at16610 Quayside Drive, Milton, Georgia. An extension cord powering an impact wrench did not have a continuous path to ground as the ground pin of the three prong plug was missing.
Recent events (1)
  • — Z (O) $0

1926.454 A

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.    a) Front of residence located at 16610 Quayside Drive, Milton, Georgia. The employer did not ensure that the employees working on the fabricated frame scaffold were trained by a qualified person to recognize and control or minimize the hazards associated with the type of scaffold being used.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337307813.