On , OSHA opened a referral safety inspection of GREENWAY RECYCLING, INC. in 357 NORTH FORT AVENUE, SPRINGFIELD, MO 65802 (NAICS 423930). OSHA activity number 337323414.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Greenway Recycling, INC. — free Get an email when a new federal OSHA severe-injury report for Greenway Recycling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
357 NORTH FORT AVENUE
City
SPRINGFIELD
State
MO
ZIP
65802
Mailing
P.O. BOX 178, FORDLAND, MO 65652
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
15
Ownership type
A

11 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    (a) The Plastic Sort Line:  Employees were exposed to the level above the Plastic Sort Line which did not have a top rail and midrail and was 13 feet above the ground floor.    (b) Platform to Entrance Door to Warehouse: The concrete platform by the outside entry door to the Warehouse building did not have a toprail and midrail, and was over four feet above the ground.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.134 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) Employees were being required to wear 3M 8247, and/or 3M 8210 N195 Particulate respirators when entering the pit area under the Cardboard Baler in the Tipping Area/Warehouse and there was no written respiratory protection program.  Employees were not provided a medical evaluation prior to being required to use the 3M 8247, and 3M 8210 N195 Particulate respirators.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.134 D

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d):  The employer did not evaluate respiratory hazard(s) in the workplace, identify relevant workplace and user factors, and base respirator selection on these factors:    (a) Tipping Area/Warehouse:  Employees are using 3M 8247, and 3M 8210 N195 Particulate Respirators when entering the pit area under the Cardboard baler and the employer did not identify relevant workplace and user factors, and base respirator selection on these factors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C04

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:    (a) Area under cardboard baler was a permit confined space and there was no written permit confined space entry program for this location as the safety and health programs were all at the other location in Fordland, Missouri. The confined space entry program was not being implemented.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.176 B

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    (a) Plastic bales were stored on the east side outside of the Warehouse building. The plastic bales were stacked 4 high and on a slope.  The plastic bales were not stable as an accident occurred on or about November 6, 2012 where two or more plastic bales fell over crushing a temporary service employee.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.178 L01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    (a)  Employees were not trained and evaluated by Greenway Recycling dba New America Recycling to operate the forklift prior to permitting the employees to operate the forklift.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.304 G05

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    (a) Tipping Floor/Warehouse:  The Craftsman air compressor was not grounded exposing employees to electrical hazards. The ground pin was absent.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.305 B02 I

Serious Gravity 5 3 instances 15 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    (a) Employee breakroom, warehouse:  An electrical outlet box, and an electrical light switch did not have a faceplate.    (b) Employee restroom, warehouse:  The electrical light switch in the employee restroom did not have a faceplate.    (c) Warehouse, east entrance:  The junction box on the east wall of the Tipping Floor did not have a cover.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) Plastic Sort Line:  The strain relief was not adequate as the exterior insulation had pulled back next to the motor for the conveyor belt exposing interior wiring.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.1200 E01

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) Employees were exposed to hazardous chemicals, such as, but not limited to, Hydraulic fluid, and Shell Rotella T Triple Protection Motor Oil, diesel fuel, and there was no written hazard communication program specifying labelling and other forms of warning for chemicals, how material safety data sheets are to be maintained in the workplace, and how employees will be given information and training.  The hazard communication program was being kept in the other site location in Fordland, Missouri.  Chemicals, such as, but not limited to, the motor oil has been in a Hiland Dairy milk jug, which did not have the identity, and hazard warning on the bottle.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1904.31 B02

Other-than-serious 2 instances 2 exposed
Issued
Jan 30, 2013
Abate by
Mar 6, 2013
Penalty
Initial $400 · Current $280 Reduced
29 CFR 1904.31(b)(2): Employees from a temporary help service supervised on a day-to-day basis sustained an injury or illness and that was not recorded on the OSHA 300 log(s)    (a)  Greenway Recycling did not record injuries or illnesses for employees from Penmac which they supervised on a day-to-day basis and the injuries or illnesses were not recorded on the OSHA 300 logs, such as, but not limited to, an accident occurring on October 12, 2012 where an employee had a shoulder strain.    (b) Greenway Recycling did not record injuries or illnesses for employees from Penmac which they supervised on a day-to-day basis and the injuries or illnesses were not recorded on the OSHA 300 log, including an accident, which occurred on October 16, 2012 where an employee was punctured by a needle.