JOHNSTON, RI —
OSHA Inspection: NORMAN SANVILLE, JR.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NORMAN SANVILLE, JR. in 15 INDUSTRIAL LANE, JOHNSTON, RI 02919 (NAICS 321999). OSHA activity number 337345037.
Where did this inspection happen?
- Establishment
- NORMAN SANVILLE, JR.
- Site address
- 15 INDUSTRIAL LANE
- City
- JOHNSTON
- State
- RI
- ZIP
- 02919
- Mailing
- 25 LARGO ROAD, WARWICK, RI 02889
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 3
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.22 A02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: Wood shop: On or about 11/14/2012, the vertical and horizontal surfaces were allowed to collect excessive amounts of combustible wood dust.
Recent events (1)
- — Z (S) $2800
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Wood shop: On or about 11/14/2012, the employer did not provide approved electrical equipment and associated wring for Class II hazardous locations whereby the wood shop had an excessive accumulation of combustible wood dust.
Recent events (1)
- — Z (S) $0
1910.213 A09
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts shall be guarded in accordance with the specific requirements of 1910.219. Wood shop: On or about 11/14/2012, employees were operating wood working equipment whereby all gears, shafts, and moving parts were not guarded in the following instances: (a) The two Craftsman 8 circular table saws did not have a guard around the belt to protect employees from rotating parts; (b) The Central Machinery belt sander did not have a guard around the belt to protect employees from rotating parts; and (c) The Delta band saw did not have a guard around the belt to protect employees from rotating parts.
Recent events (1)
- — Z (S) $2800
1910.213 B03
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: Wood shop: On or about 11/14/2012, provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure in the following instances: (a) The two Craftsman 8 circular table saws did not have anti-restart devices installed; (b) The Central Machinery belt sander did not have an anti-restart devices installed; and (c) The Delta band saw did not have an anti-restart device installed.
Recent events (1)
- — Z (S) $2000
1910.213 D01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.213(d)(1): Circular hand-fed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Wood Shop: On or about 11/14/2012, employees were operating table saws whereby they were not guarded by an automatically adjusting hood in the following instances: (a) East wall - Craftsman 8 circular table saw was not guarded by an automatically adjusting hood; (b) Center Floor - Craftsman 8 circular table saw was not guarded by an automatically adjusting hood.
Recent events (1)
- — Z (S) $2800
1910.213 R04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(r)(4): Suitable guard(s) and exhaust hood(s) were not provided to reduce to a minimum the hazard due to the point of operation: Wood Shop: A suitable guard was not provided to reduce to a minimum the hazard due to the point of operation of the Delta 10 inch miter saw.
Recent events (1)
- — Z (S) $0
1910.213 I01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: Wood Shop: On or about 11/14/2012, employees were operating the Delta bandsaw whereby the bandsaw wheel was not guarded to protect the operator from contact with rotating blade.
Recent events (1)
- — Z (S) $2800
1910.213 P04
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points: Wood Shop, Center Floor: On or about 11/14/2012, The Central Machinery belt sander was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points.
Recent events (1)
- — Z (S) $1600
1910.303 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: Wood Shop, East Wall: On or about 11/14/2012, employees were operating the Craftsman 8 circular table saw whereby the cord insulation was damaged.
Recent events (1)
- — Z (S) $2800
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Wood Shop, East wall: On or about 11/14/2012, the flexible power cord on the Craftsman 8 inch circular table saw was not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.
Recent events (1)
- — Z (S) $0
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Wood Shop: On or about 11/14/2012, employees were operating the Delta 10 inch Power Miter saw whereby the grounding pin was not installed on the power cord.
Recent events (1)
- — Z (S) $2000
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Wood Shop, center floor: On or about 11/14/2012, employees were operating the Central Machinery belt sander and the Delta band saw which were connected to the wall out let by an extension cord that was being used in lieu of permanent wiring.
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 321999)
LAURINBURG, NC—2026-07-14
161549 - AMERICAN WOOD FIBERS, INC.
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH WILKESBORO, NC—2026-07-07
161501 - MILLER BEE SUPPLY, INC.
MIAMI, FL—2026-06-26
FLORIDA LUMBER COMPANY
PLATO, MN—2026-06-25
111471 - GREAT OAK EQUINE
More inspections in RI
PAWTUCKET, RI—2026-07-16
INTERNATIONAL PACKAGING CORPORATION
WARWICK, RI—2026-07-16
LYON PROPERTY MANAGEMENT, LLC
LINCOLN, RI—2026-07-14
TFORCE FREIGHT
JOHNSTON, RI—2026-07-14
WEST BAY RESIDENTIAL SERVICES INC.
NEWPORT, RI—2026-07-10
STEVEN POSTHUMA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337345037.