TUCKER, GA —
OSHA Inspection: COMCAST OF GEORGIA VIRGINIA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMCAST OF GEORGIA VIRGINIA, INC. in 2140 FLINTSTONE DRIVE, TUCKER, GA 30084 (NAICS 515210). OSHA activity number 337350433.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMCAST OF GEORGIA VIRGINIA, INC.
- Site address
- 2140 FLINTSTONE DRIVE
- City
- TUCKER
- State
- GA
- ZIP
- 30084
- Mailing
- 2925 COURTYARDS DRIVE, NORCROSS, GA 30084
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 515210
- Employees
- 32
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 M05 I
- Issued
- Dec 12, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls were not netralized, power was not shut off, and brakes set: On or about Tuesday November 13, 2012 at aisles 13 and 14 of the warehouse storage rack storage areas; The standup order picker was left unattended with the power switch on and several pallets loaded with products on the forks of the equipment elevated 19 inches above the ground level.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.178 P01
- Issued
- Dec 12, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $5,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Where powered industrial trucks were found to be in need of repair, defective, or in any way unsafe, the trucks were not taken out of service until they had been restored to safe operating condition: On or about Tuesday November 13, 2012 at gate entrance of the warehouse production area; Where a powered industrial truck was missing bolt and had a loose bolt on the driver side of the metal mast support bracket the employer failed to inspect the powered industrial truck prior to use.
Recent events (2)
- — I (S) $0
- — Z (S) $5100
1910.178 Q07
- Issued
- Dec 12, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $0 · Current $3,060
General-duty citation text
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift: On or about Tuesday November 13, 2012 in the warehouse production area; The employee operating the powered industrial truck did not inspect the equipment for deficiencies such as but not limited to one missing bolt and one loose bolt on the driver side of the metal mast support bracket.
Recent events (2)
- — I (S) $3060
- — Z (S) $0
1910.157 C04
- Issued
- Dec 12, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: On or about Tuesday November 13, 2012 in the customer pre-measurable equipment (CPE) area; The fire extinguisher that indicates that the gauge reading was in the red zone recharge and was not taken out of service.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Dec 12, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: On or about Tuesday November 13, 2012 throughout the production area; The portable fire extinguishers were not inspected monthly for deficiencies where the pressure gauge reading indicated that the fire extinguisher needed to be re-charged.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 515210)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337350433.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.