LAKE CHARLES, LA —
OSHA Inspection: AAA MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AAA MASONRY, INC. in NEXT TO 4313 LAKE ST., LAKE CHARLES, LA 70605 (NAICS 238140). OSHA activity number 337369417.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AAA MASONRY, INC.
- Site address
- NEXT TO 4313 LAKE ST.
- City
- LAKE CHARLES
- State
- LA
- ZIP
- 70605
- Mailing
- 1820 NICHOLAS ST., LAKE CHARLES, LA 70605
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Dec 19, 2012
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. a) Lake St., Lake Charles, LA; employees were exposed to falling objects from heights up to approximately 18 feet while working from a scaffold that did not have toe boards or other devices used to prevent falling debris. Employees were applying brick to the exterior of a building. Potential falling objects from overhead included, but may not be limited to, bricks, hand tools, and five gallon buckets.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
1926.451 H02 II
- Issued
- Dec 19, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 x 1 1/2 inch (2 x 4 cm) wood or equivalent may be used in lieu of toeboards; a) Lake St., Lake Charles, LA; the employer failed to ensure toeboards were installed on a 13 foot high scaffold platform that held bricks and other material. Employees working underneath were exposed to a struck-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.102 A01
- Issued
- Dec 19, 2012
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. a) Lake Charles, LA; the employer failed to ensure an employee using a Dewalt screwgun to install wall ties wore eye protection. The employee was exposed to an injury.
Recent events (2)
- — I (S) $0
- — Z (S) $1020
1926.451 G01 VI
- Issued
- Dec 19, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity). a) Lake St., Lake Charles, LA; employees were observed working from a scaffold approximately 13 feet above the ground that did not have a midrail on the level the employees were working from.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 E01
- Issued
- Dec 19, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a) Lake St., Lake Charles, LA; the employer failed to ensure a scaffold used for overhand bricklaying was equipped with a ladder for access and egress. The work platform was approximately 13 feet above the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
More inspections at AAA Masonry, INC.
View AAA Masonry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337369417.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.