HONOLULU, HI —
OSHA Inspection: FUJIYA HONPO INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FUJIYA HONPO INC in 454 WAIAKAMILO RD, HONOLULU, HI 96817 (NAICS 311812). OSHA activity number 337375414.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FUJIYA HONPO INC
- Site address
- 454 WAIAKAMILO RD
- City
- HONOLULU
- State
- HI
- ZIP
- 96817
- Mailing
- 454 WAIAKAMILO RD, HONOLULU, HI 96817
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 17
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 29, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $2,800 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about November 15th, 2012, and times prior thereto, there were no lockout tagout procedures developed for multi energy equipment such as the Tufu machine. Employee exposed to a caught-in and/or electrical hazard. The machine as a minimum had pneumatic and electrical energy. The official name of the machine is a Cooker Mist, model number #380004B, Serial #B2606.
Recent events (2)
- — I (S) $2450
- — Z (S) $2800
1910.147 C07 I
- Issued
- Nov 29, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) On or about November 15th, 2012, and times prior thereto, the employer did not provide training to employees on how to safety control potential energy sources, when setting up and cleaning equipment. Employees exposed to an electrical shock and/or caught-in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Nov 29, 2012
- Abate by
- Dec 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
2CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about November 15th, 2012, and times prior thereto, the employer did not conduct a periodic inspection of the energy control (lockout tagout) procedures. Employees exposed to an electrical shock and/or caught-in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 G02
- Issued
- Nov 29, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) On or about November 15, 2012, and time prior thereto, employees are required to use fire extinguisher and there was no initial fire extinguisher training or annual training. Employee(s) exposed to delay of getting out the building and subsequently smoke inhalation and/or burns.
Recent events (2)
- — I (O) $0
- — Z (S) $1200
1910.263 E01 I
- Issued
- Nov 29, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.263(e)(1)(i): Mixers with external power application shall have all belts, chains, gears, pulleys, sprockets, clutches, and other moving parts completely enclosed. a) On or about November 15th, 2012, and times prior thereto, the first mixer next to the Tufu machine had an unguarded horizontal belt and pulley. Employee(s) exposed to a caught-in hazard. The opening was measured at 17"x 3". The number on the mixer was 9.0.7.1. b) On or about November 15th, 2012, and times prior thereto, the second mixer from the Tufu machine had an unguarded horizontal belt and pulley. Employee(s) exposed to a caught-in hazard. The opening was measured at 17"x 3". The number on the mixer was 9.6.8.9. c) On or about November 15th, 2012, and times prior thereto, the third mixer from the Tufu machine had an unguarded vertical belt and pulley. Employee(s) exposed to a caught-in hazard. The opening was measured at 4" x 24" on both sides. The mixer was made in Japan and had a Baldor motor on it with model number L1209A.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1910.263 E01 VIII
- Issued
- Nov 29, 2012
- Abate by
- Apr 1, 2013
- Penalty
- Initial $2,800 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.263(e)(1)(viii): Horizontal dough mixer(s) were not equipped with a full enclosure over the bowl while the agitator was in motion: a) On or about November 15th, 2012, and times prior thereto, the first mixer next to the Tufu machine was not equipped with a full enclosure guard when mixing. Employee(s) exposed to a caught-in hazard. The number on the mixer was 9.0.7.1. b) On or about November 15th, 2012, and times prior thereto, the second mixer from the Tufu machine was not equipped with a full enclosure guard when mixing. Employee(s) exposed to a caught-in hazard. The number on the mixer was 9.6.8.9. c) On or about November 15th, 2012, and times prior thereto, the third mixer from the Tufu machine was not equipped with a full enclosure guard when mixing. Employee(s) exposed to a caught-in hazard. The mixer was made in Japan and had a Baldor motor on it with model number L1209A. d) On or about November 15th, 2012, and times prior thereto, the 4th mixer from to the Tufu machine was not equipped with a full enclosure guard when mixing. Employee(s) exposed to a caught-in hazard. The number on the mixer was 0561.
Recent events (2)
- — I (S) $2450
- — Z (S) $2800
1910.303 B01
- Issued
- Nov 29, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) On or about November 15th, 2012 , and times prior thereto, near the main walkway, there is a live conductor laying on the floor. Employee(s) exposed to an electrical shock.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1910.303 B08 I
- Issued
- Nov 29, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $2,000 · Current $1,650 Reduced
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it was mounted: a) On or about November 15th, 2012 , and times prior thereto , near the Rainier oven the pedestal metal junction box was not secured to the conduit. Employees exposed to an electrical shock.
Recent events (2)
- — I (S) $1650
- — Z (S) $2000
1910.305 B01 II
- Issued
- Nov 29, 2012
- Abate by
- Dec 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about November 15th, 2012, and times prior there to, in the middle of the room, the receptacle box had the knockout plug missing. Employee(s) exposed to an electrical shock and a fire deficiency with the potential for the flour dust collection in opening.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 J02 IV
- Issued
- Nov 29, 2012
- Abate by
- Apr 1, 2013
- Penalty
- Initial $2,800 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: a) On or about November 15, 2012, and times prior thereto, the electrical equipment such receptacles were not approved for wet conditions. Employees exposed to an electrical shock.
Recent events (2)
- — I (S) $2450
- — Z (S) $2800
1910.305 J02 VII
- Issued
- Nov 29, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed: a) On or about November 15, 2012, and times prior thereto, the electrical receptacles did not have weatherproof enclosures in wet conditions.. Employee(s) exposed to an electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.32 B03
- Issued
- Nov 29, 2012
- Abate by
- Dec 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(b)(3): The 300A annual summary was not certifyed by a company executive to ensure that he or she has examined the OSHA 300 Log and that he or she reasonably believes, based on his or her knowledge of the process by which the information was recorded, that the annual summary is correct and complete. a) On or about November 15, 2012, and times prior thereto, the employer did not certify the annual summary for the year 2011. b) On or about November 15, 2012, and times prior thereto, the employer did not certify the annual summary for the year 2010. c) On or about November 15, 2012, and times prior thereto, the employer did not certify the annual summary for the year 2009.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.151 B
- Issued
- Nov 29, 2012
- Abate by
- Apr 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(b): There was neither an infirmary, clinic, or hospital used for the treatment of all injured employees in near proximity to the workplace nor a person or persons adequately trained to render first aid: a) On or about November 15, 2012, and times prior thereto, there was no one on site trained to render first aid in a timely manner. Employee(s) exposed to delay of medical response
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Fujiya Honpo INC
View Fujiya Honpo INC's full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337375414.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.