PAULSBORO, NJ —
OSHA Inspection: AMSPEC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of AMSPEC in 1300 NORTH DELAWARE STREET, PAULSBORO, NJ 08066 (NAICS 541380). OSHA activity number 337415624.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMSPEC
- Site address
- 1300 NORTH DELAWARE STREET
- City
- PAULSBORO
- State
- NJ
- ZIP
- 08066
- Mailing
- 1300 NORTH DELAWARE STREET, PAULSBORO, NJ 08066
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541380
- Employees
- 21
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 B04 I
- Issued
- Mar 4, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or a) Storage Area / Rear of the Building: 2 Oxydegn cylinders were stored 4 inches from 2 Hydrogen cylinders, on or about 11/12/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $3000
1910.305 B02 I
- Issued
- Mar 4, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Storage Area / Rear of building: An electrical outlet was missing a faceplate, on or about 11/12/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $3000
1910.305 G02 III
- Issued
- Mar 4, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Laboratory / West end: Employees used the Carbon Residue Apparatus Ramsbottom ASTM D524 which had damaged strain relief, on or about 11/12/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $3000
More inspections at Amspec
View Amspec's full OSHA safety record →
More inspections in this industry (NAICS 541380)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337415624.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.