Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUSTIN BUDGET SIGNS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AUSTIN BUDGET SIGNS INC. in 6507 CIRCLE S ROAD, AUSTIN, TX 78745 (NAICS 339950). OSHA activity number 337456016.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Austin Budget Signs INC. — free Get an email when a new federal OSHA severe-injury report for Austin Budget Signs INC. is published. One employer, no account, unsubscribe in one click.
Site address
6507 CIRCLE S ROAD
City
AUSTIN
State
TX
ZIP
78745
Mailing
3904 WAREHOUSE ROW, STE D, AUSTIN, TX 78704
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
6
Ownership type
A

5 citations on file for this inspection.

1910.67 C02 V

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2013
Abate by
Jan 22, 2013
Penalty
Initial $2,800 · Current $900 Reduced
29 CFR 1910.67(c)(2)(v):     A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift.    On or about 16 November 2012, an employee was working from within a basket that was attached to a telescoping ladder boom without the use of fall protection, exposing the employee to a fall hazard of approximately 20 feet or higher from being ejected out of the basket.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure employees utilize fall protection when elevated within a boom or basket from an aerial lift.
Recent events (2)
  • — I (S) $900
  • — Z (S) $2800

1910.333 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2013
Abate by
Jan 22, 2013
Penalty
Initial $2,800 · Current $900 Reduced
29 CFR 1910.333(c)(3):     When work was to be performed near overhead lines, the lines were not deenergized and grounded, nor were other protective measures provided before work was started.    On or about 16 November 2012, an employee was working from inside a basket attached to a ladder crane that was within 10 feet from an overhead power line at approximately 7.2 Kv without the lines being deenergized and grounded, or some other protective means in place, exposing the employee to an electrical hazard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure arrangements are made with the power company to ensure lines are deenergized and grounded, or that other precautions are utilized prior to work beginning near the lines.
Recent events (2)
  • — I (S) $900
  • — Z (S) $2800

1910.333 C03 I A 1

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2013
Abate by
Jan 22, 2013
Penalty
Initial $2,800 · Current $500 Reduced
29 CFR 1910.333(c)(3)(i)(A)(1):     When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location was not such that the person and the longest conductive object he or she could contact cannot come closer to any unguarded, energized overhead line than 10 feet (305 cm).    On or about 16 November 2012,  an employee was changing light bulbs from an elevated sign that was within 10 feet of an overhead energized power line at ~7.2 Kv. The employee had an approximately 12 foot piece of aluminum trim in his hands when it came into contact with the power line, exposing the employee to electrical hazards.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure personnel working near overhead power lines stay at least 10 feet away from the lines, or the length of the longest conductive object that the personnel may be in contact with while working.
Recent events (2)
  • — I (S) $500
  • — Z (S) $2800

1910.333 C03 III A

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2013
Abate by
Jan 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(3)(iii)(A):     Vehicles or mechanical equipment capable of having parts of their structures elevated near energized overhead lines were not operated so that a clearance of 10 feet (305 cm) was maintained.    On or about 16 November 2012, an employee was working from a basket that was elevated approximately 20 feet to change bulbs in a sign which was within 10 feet of an overhead energized line, exposing the employee to electrical hazards of up to approximately 7200 volts and approximately 100 amps.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure safe work practices include being more than 10 feet away from energized overhead lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 C06

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2013
Abate by
Jan 22, 2013
Penalty
Initial $2,800 · Current $500 Reduced
29 CFR 1910.333(c)(6):     Where an employee is required to handle long dimensional conductive objects in areas with exposed live parts, the employer did not institute work practices (such as the use of insulation, guarding, and material handling techniques) to minimize the hazard.    On or about 16 November 2012, an employee was working from a basket at a height of approximately 20 feet changing light bulbs from a sign when the aluminum trim for the sign he was holding came into contact with an overhead energized line at approximately 7200 volts, exposing the employee to an electrical hazard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure implementing safe work practices that help to minimize the hazard of coming into contact with live exposed parts or energized overhead lines.
Recent events (2)
  • — I (S) $500
  • — Z (S) $2800

View Austin Budget Signs INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337456016.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.