Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CREATIVE MALNOVE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CREATIVE MALNOVE, LLC in 91-310 KAUHI ST, KAPOLEI, HI 96707 (NAICS 326112). OSHA activity number 337471627.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Creative Malnove, LLC — free Get an email when a new federal OSHA severe-injury report for Creative Malnove, LLC is published. One employer, no account, unsubscribe in one click.
Site address
91-310 KAUHI ST
City
KAPOLEI
State
HI
ZIP
96707
Mailing
91-310 KAUHI ST, KAPOLEI, HI 96707
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
16
Ownership type
A

8 citations on file for this inspection.

1910.147 C02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $1,700 · Current $1,275 Reduced
29 CFR 1910.147(c)(2)(ii):     Where an energy isolating device is capable of being locked out, the employer's energy control program under paragraph (c)(1) of this section did not utilize lockout:    (a) Main Shop Kluge foil stamp press: On 11-19-12 and at times prior thereto, lockout devices were not applied to the machine's power switch and power supply panel to prevent accidental energization.      NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $1700

1910.147 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii):     Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to: [A] A specific statement of the intended use of the procedure; and [B] Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    (a) Main shop: On 11-19-12 and at times prior thereto, lack of specific lock out procedures and enforcement resulted in workers being exposed to accidental start-up of a Kluge stamp press that was under repair.    NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i):     The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    (a) Establishment: On 11-19-2012 and at times prior thereto, The employer provided only general training that was not specific ti the establishment or equipment at the site.      NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 24, 2013
Penalty
Initial $2,040 · Current $1,530 Reduced
29 CFR 1910.303(b)(7)(iv):     There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:    (a) Machine # 31 a Post paper folder: On 11-19-12 and at times prior thereto, a flexible cord was no longer providing protection to insulated conductors due to severe cracks and flaking of the outer cover.    NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2040

1910.303 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    (a) International Paper Box Machine Co, Ser# FZ-K344: On 11-19-12 and at times prior thereto, 110v bare conductors of a switch wire were exposed to contact with workers and dangled within 1.5 inches of the metal frame of the machine.      NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 3 instances 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) International Paper Box Machine Co, Ser# FZ-K344: On 11-19-12 and at times prior thereto, a conduit box knockout was missing and the hole was not covered.    (b) International Paper Box Machine Co, Ser# FZ-K344: On 11-19-12 and at times prior thereto, a control switch box threaded fitting was missing and the hole was not covered.    (c) Post paper folder machine # 31: On 11-19-12 and at times prior thereto, a control switch box threaded fitting was missing and the hole was not covered.      NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):     Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) Employers Machine # 31 (no MFG ID plate found), a Post paper box folder: On 11-19-2012 and at times prior thereto, the outer cover was pulled from the releife devise of a cord end fitting.      NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Jan 4, 2013
Abate by
Jan 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) Main shop: On 11-19-2012 and at times prior thereto, pressure was greater than 100 p.s.i at the tip of a short, compressed air, trigger nozzle used to blow down equipment.    NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Creative Malnove, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337471627.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.