Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: US DEPT OF JUSTICE - DEA LOS ANGELES FIELD DIV

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of US DEPT OF JUSTICE - DEA LOS ANGELES FIELD DIV in 1340 WEST 6TH ST, LOS ANGELES, CA 90017 (NAICS 922120). OSHA activity number 337487011.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Dept of Justice - DEA LOS Angeles Field DIV — free Get an email when a new federal OSHA severe-injury report for US Dept of Justice - DEA LOS Angeles Field DIV is published. One employer, no account, unsubscribe in one click.
Site address
1340 WEST 6TH ST
City
LOS ANGELES
State
CA
ZIP
90017
Mailing
1340 WEST 6TH ST, LOS ANGELES, CA 90017
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922120
Employees
40
Ownership type
D

10 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Basement: On or about 20NOV12, 1403hrs, drill presses in use lacked a method of machine guarding to protect employees from flying chips and sparks.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    Basement: On or about 20NOV12, 1403hrs, a floor drill press resting upon a wheeled furniture dolly was used by employees.
Recent events (1)
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    Basement: On or about 20NOV12, 1416hrs, a portable air compressor used by the employees for cleaning was not reduced to less than 30 p.s.i.:
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 2 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Basement: On or about 20NOV12, 1401hrs, a flexible extension cord was used to provide 120VAC electrical service to a power strip.     (b) Basement: On or about 20NOV12, 1415hrs, plastic electrical boxes were fashioned into service as snap switch boxes for 120VAC electrical service.    (c) Basement: On or about 20NOV12, 1422hrs, a metal outlet box was used in conjunction with a spliced flexible cord to provided 120VAC electrical service.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    Basement: On or about 20NOV12, 1416hrs, employees were exposed to inadvertent contact with live 240VAC conductors on an air compressor where the cover was not replaced.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV D

Serious Gravity 5 1 instance 45 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces:    Basement: On or about 20NOV12, 1415hrs, The employer had several flexible cords, and extension cords fastened to the walls, ceilings structures, and fences.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:     Basement: On or about 20NOV12, 1422hrs, exposed conductors were not provided protection from a pull being directly transmitted to joints or terminal screws where the sheathing of a flexible cord was pulled back from the connection plug.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 45 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    At the facility: On or about 20NOV12, 1200hrs, The employer did not provide a hazardous communication program addressing labeling of hazardous chemicals, material safety data sheets, and training addressing the chemicals in the workplace.
Recent events (1)
  • — Z (S) $0

1960.58

Serious Gravity 5 1 instance 45 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1960.58:  The Agency did not provide training for collateral duty safety and health personnel including all members of certified occupational safety and health committees commensurate with the scope of their assigned responsibilities:    At the facility: On or about 06NOV12, 1000hrs, the employer did not provide training for collateral safety and health personnel commensurate with the scope of the assigned responsibilities.
Recent events (1)
  • — Z (S) $0

1904.32 A

Other-than-serious 1 instance 45 exposed
Issued
Dec 7, 2012
Abate by
Jan 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a): The employer did not ensure that at the end of the year an annual summary of injuries and illnesses on the OSHA 300 Log was created, certified and posted:    At the facility: On or about 20NOV12, 1200hrs, the employer failed to create and certify an annual summary of injuries and illnesses for the last five years. The employer did not maintain a log of recordable injuries and illnesses in order to create the annual summary.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337487011.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.