HUDSON, NY —
OSHA Inspection: SAM SPRAGIS GENERAL CONTRACTOR
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SAM SPRAGIS GENERAL CONTRACTOR in 445 WARREN STREET, HUDSON, NY 12534 (NAICS 238350). OSHA activity number 337494629.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAM SPRAGIS GENERAL CONTRACTOR
- Site address
- 445 WARREN STREET
- City
- HUDSON
- State
- NY
- ZIP
- 12534
- Mailing
- 150 UNDERHILL ROAD, HILLSDALE, NY 12529
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Jan 2, 2013
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports: (a) Front of Building - on or about November 21, 2012 - the tubular welded framed scaffold system did not have a fully planked scaffold deck. Ground to work deck elevation was approximately 17 feet.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
1926.451 G01 VII
- Issued
- Jan 2, 2013
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: (a) Front of Building - on or about November 21, 2012 - the working level of this scaffold system was not equipped with guardrails. Elevation of the work deck was approximately 17 feet above the ground.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
1926.451 F07
- Issued
- Jan 2, 2013
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled or altered by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: (a) Front of Building - on or about November 21, 2012 - the tubular welded framed scaffold system was not designed and erected by a scaffold competent person.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
1926.454 A
- Issued
- Jan 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) Front of Building - on or about November 21, 2012 - the employer did not train employees in the recognition and avoidance of hazards on the tubular welded framed scaffold system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 C03
- Issued
- Jan 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(3): Frames and panels were not joined together vertically by coupling or stacking pins or equivalent means: (a) Front of Building - on or about November 21, 2012 - the vertically stacked frames for the tubular welded framed scaffold system were not joined together by the use of coupling pins or equivalent means.