CRANSTON, RI —
OSHA Inspection: J. COYNE COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of J. COYNE COMPANY in WEST RD & FLEMING RD, CRANSTON, RI 02920 (NAICS 238220). OSHA activity number 337496426.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. COYNE COMPANY
- Site address
- WEST RD & FLEMING RD
- City
- CRANSTON
- State
- RI
- ZIP
- 02920
- Mailing
- 127 FLETCHER AVE, CRANSTON, RI 02920
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.21 B02
- Issued
- Dec 27, 2012
- Abate by
- Jan 14, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: (a) Jobsite: The employer did not instruct each employee in the recognition and avoidance of unsafe conditions present during the refueling with gasoline of the Lincoln Electric Ranger 225 Welders, for a jobsite located in Cranston RI on or about 11-20-12.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.651 I01
- Issued
- Dec 27, 2012
- Abate by
- Jan 14, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees. (a) Jobsite - Excavation VS-1 - VS-3: The concrete duct bank running through the excavation, which was exposed during the excavation process, was not provided with a support system, such as but not limited to underpinning, to ensure the stability of this structure for the protection of employees working in the excavation, for a jobsite located in Cranston RI on or about 11-23-12.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.652 A01
- Issued
- Dec 27, 2012
- Abate by
- Jan 14, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: (a) Jobsite - Valve Station 1: Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section, for a jobsite located in Cranston RI on or about 11-29-12.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000