WAUKEGAN, IL —
OSHA Inspection: PROFESSIONAL ROOFING AND CARPENTRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PROFESSIONAL ROOFING AND CARPENTRY, INC. in 1700 LEWIS, WAUKEGAN, IL 60085 (NAICS 238160). OSHA activity number 337521421.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROFESSIONAL ROOFING AND CARPENTRY, INC.
- Site address
- 1700 LEWIS
- City
- WAUKEGAN
- State
- IL
- ZIP
- 60085
- Mailing
- 3525 TAMARIND DRIVE, NORTHBROOK, IL 60062
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B10
- Issued
- Nov 27, 2012
- Abate by
- Dec 3, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) Employees were not protected from the hazard of falling approximately 25 feet from the edge of the roof deck while engaged in roofing activities without the benefit of fall protection or a safety monitor. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B01
- Issued
- Nov 27, 2012
- Abate by
- Dec 3, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Employees were exposed to the hazard of falling from an elevation of approximately 25 feet where a portable extension ladder provided for roof access and egress did not extend at least 3 feet above the landing surface of the roof. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B16
- Issued
- Nov 27, 2012
- Abate by
- Dec 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) Employees were exposed to the hazard of falling from an elevation of approximately 25 feet where a portable extension ladder used for roof access and egress had damaged cleats/footpads. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.