Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOLMET TECHNOLOGIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SOLMET TECHNOLOGIES, INC. in 2716 SHEPLER CHURCH AVENUE SW, CANTON, OH 44706 (NAICS 332111). OSHA activity number 337543011.

Watch Solmet Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Solmet Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2716 SHEPLER CHURCH AVENUE SW
City
CANTON
State
OH
ZIP
44706
Mailing
2716 SHEPLER CHURCH AVENUE SW, CANTON, OH 44706
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332111
Employees
32
Ownership type
A

3 citations on file for this inspection.

1910.178 L04 III

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.178(l)(4)(iii):     An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    On and before November 27, 2012, evaluations had not been completed every three years for company employees required to operate forklifts.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.179 J02

Serious Gravity 5 1 instance 26 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1785.00 Reduced
29 CFR 1910.179(j)(2):   The following items were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections:    On or about November 27, 2012, cranes in the facility were not inspected in accordance with 1910.179(j)(2)(i) through 1910.179(j)(2)(iv).    ABATEMENT NOTE:    1910.179(j)(2)(i): All functional operating mechanisms for maladjustment interfering with proper operation. Daily.    1910.179(j)(2)(ii): Deterioration or leakage in lines, tanks, valves, drain pumps, and other parts of air or hydraulic systems. Daily.    1910.179(j)(2)(iii): Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. For hooks with cracks or having more than 15 percent in excess of normal throat opening or more than 10 twist from the plane of the unbent hook refer to paragraph (l)(3)(iii)(a) of this section.    1910.179(j)(2)(iv): Hoist chains, including end connections, for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.157 E02

Other-than-serious 1 instance 35 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2):     Portable fire extinguishers were not visually inspected at least monthly:    The company maintained portable fire extinguishers throughout the facility for use with incipient stage fires. On or about November 27, 2012, visual monthly inspections had not been conducted.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337543011.