CANTON, OH ·
OSHA Inspection: SOLMET TECHNOLOGIES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SOLMET TECHNOLOGIES, INC. in 2716 SHEPLER CHURCH AVENUE SW, CANTON, OH 44706 (NAICS 332111). OSHA activity number 337543011.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLMET TECHNOLOGIES, INC.
- Site address
- 2716 SHEPLER CHURCH AVENUE SW
- City
- CANTON
- State
- OH
- ZIP
- 44706
- Mailing
- 2716 SHEPLER CHURCH AVENUE SW, CANTON, OH 44706
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 32
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.178 L04 III
- Issued
- Jan 30, 2013
- Abate by
- Feb 19, 2013
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On and before November 27, 2012, evaluations had not been completed every three years for company employees required to operate forklifts.
Recent events (2)
- · I (S) $1428
- · Z (S) $2380
1910.179 J02
- Issued
- Jan 30, 2013
- Abate by
- Mar 19, 2013
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.179(j)(2): The following items were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: On or about November 27, 2012, cranes in the facility were not inspected in accordance with 1910.179(j)(2)(i) through 1910.179(j)(2)(iv). ABATEMENT NOTE: 1910.179(j)(2)(i): All functional operating mechanisms for maladjustment interfering with proper operation. Daily. 1910.179(j)(2)(ii): Deterioration or leakage in lines, tanks, valves, drain pumps, and other parts of air or hydraulic systems. Daily. 1910.179(j)(2)(iii): Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. For hooks with cracks or having more than 15 percent in excess of normal throat opening or more than 10 twist from the plane of the unbent hook refer to paragraph (l)(3)(iii)(a) of this section. 1910.179(j)(2)(iv): Hoist chains, including end connections, for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected.
Recent events (2)
- · I (S) $1785
- · Z (S) $2975
1910.157 E02
- Issued
- Jan 30, 2013
- Abate by
- Feb 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: The company maintained portable fire extinguishers throughout the facility for use with incipient stage fires. On or about November 27, 2012, visual monthly inspections had not been conducted.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332111)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 337543011.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.