OSHA Inspection: ENERSYS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ENERSYS in 80 STEWART AVENUE, WASHINGTON, PA 15301 (NAICS 335911). OSHA activity number 337552418.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Enersys — free Get an email when a new federal OSHA severe-injury report for Enersys is published. One employer, no account, unsubscribe in one click.
Establishment
ENERSYS
Site address
80 STEWART AVENUE
City
WASHINGTON
State
PA
ZIP
15301
Mailing
80 STEWART AVENUE, WASHINGTON, PA 15301
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335911
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.106 D07 III

Other-than-serious 1 instance 3 exposed
Issued
Feb 13, 2013
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.106(d)(7)(iii): Open flames and smoking were permitted in flammable or combustible liquid storage areas:    a)  At the facility, on or about November 27, 2012 - An open flame coming from a stove top was in a flammable liquid storage area.
Recent events (2)
  • — I (O) $2250
  • — Z (S) $3000

1910.107 B05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 13, 2013
Penalty
Initial $4,000 · Current $3,000 Reduced
29 CFR 1910.107(b)(5)(i):  Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained:    a)  At the facility, on or about November 27, 2012 - A dry type spray booth did not have a visible gauge, audible alarm, or pressure activated device installed to insure air velocity is maintained.  Employees spray High Gloss Enamel White, Product #218-234-T, with a Graco AirPro spray gun and compressed air in the dry type spray booth.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4000

1910.107 B05 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    a)  At the facility, on or about November 27, 2012 - The dry type spray booth did not have approved automatic sprinklers on the upstream side of filters.  Employees spray High Gloss Enamel White, Product #218-234-T, with a Graco AirPro spray gun and compressed air in the dry type spray booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:    a)  At the facility, on or about November 27, 2012 - The dry type spray booth did not have a clear space of 3 feet on the left and right sides.   Employees spray High Gloss Enamel White, Product #218-234-T, with a Graco AirPro spray gun and compressed air in the dry type spray booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 D05

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(d)(5): Electric motor(s) driving exhaust fan(s) for spray booth(s) were located inside the booth(s):    a) At the facility, on or about November 27, 2012 - A Dayton Direct Drive Fan Motor, Model # 994207G, was located inside the dry type spray booth.  The Dayton Direct Drive Fan Motor was driving a Dayton 20'' Med.-Duty Exhaust Fan, Model # 4C009F.  Employees spray High Gloss Enamel White, Product #218-234-T, with a Graco AirPro spray gun and compressed air in the dry type spray booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 II

Other-than-serious 3 instances 3 exposed
Issued
Feb 13, 2013
Abate by
Apr 19, 2013
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    a) At the facility, on or about November 27, 2012 - A painter voluntarily wearing a North half-mask tight fitting respirator during spraying operations did not receive a medical evaluation.    b) At the facility, on or about November 27, 2012 - A grinder voluntarily wearing a North half-mask tight fitting respirator while grinding did not receive a medical evaluation.    c) At the facility, on or about November 27, 2012 - A welder voluntarily wearing a Miller LPR-100 half-mask tight fitting respirator while welding did not receive a medical evaluation.
Recent events (2)
  • — I (O) $2250
  • — Z (S) $3000

View Enersys's full OSHA safety record →