OSHA Inspection: BOMAT, LTD D.B.A. BONDED MATERIALS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOMAT, LTD D.B.A. BONDED MATERIALS in 91-400 KOMOHANA ST, KAPOLEI, HI 96707 (NAICS 327320). OSHA activity number 337575823.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bomat, LTD D.B.A. Bonded Materials — free Get an email when a new federal OSHA severe-injury report for Bomat, LTD D.B.A. Bonded Materials is published. One employer, no account, unsubscribe in one click.
Site address
91-400 KOMOHANA ST
City
KAPOLEI
State
HI
ZIP
96707
Mailing
91-400 KOMOHANA ST, KAPOLEI, HI 96707
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
35
Ownership type
A

5 citations on file for this inspection.

1910.23 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 8, 2013
Abate by
Mar 28, 2013
Penalty
Initial $2,380 · Current $1,785 Reduced
29 CFR 1910.23(c)(3):     Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board.    (a) Gray Mixer: On 11-27-12 and at times prior thereto, workers on a platform were 28.5 inches from the unprotected edge of a hopper that fed a running bucket lift conveyor.    NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2380

1910.219 C02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Abate by
Mar 28, 2013
Penalty
Initial $2,380 · Current $1,785 Reduced
29 CFR 1910.219(c)(2)(i):     All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    (a) Gray Mixer: On 11-27-12 and at times prior thereto, high and low speed horizontal shafts that were not guarded were located approximately 42 inches from the ground and within 17 inches of reach into the mixer.    NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2380

1910.219 E03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Abate by
Mar 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i):     Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)    (a) Gray Mixer: On 11-27-12 and at times prior thereto, vertical belts were not guarded.    NOTE 1: Some belts may be guarded with a nip-point belt and pulley guard, See 1910.219(a)(2).    NOTE 2: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II

Other-than-serious 2 instances 4 exposed
Issued
Feb 8, 2013
Abate by
Mar 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii):     Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to: [A] A specific statement of the intended use of the procedure; [B] Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    (a) Plants 1 and 2: On 11-27-12 and at times prior thereto, specific lock-out procedures for each plant were not developed to protect maintenance workers and operators from hazardous energy sources such as, but not limited to electrical, fluid, and gravity.      NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Feb 8, 2013
Abate by
Mar 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) Gray Mixer: On 11-27-12 and at times prior thereto, a conduit box knockout was missing and the hole was not covered on the gray mixer power supply control box.    NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bomat, LTD D.B.A. Bonded Materials's full OSHA safety record →