Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIVINT SOLAR INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VIVINT SOLAR INC. in 1 IONIC AVE, PARSIPPANY, NJ 07054 (NAICS 221114). OSHA activity number 337584411.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vivint Solar INC. — free Get an email when a new federal OSHA severe-injury report for Vivint Solar INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VIVINT SOLAR INC.
Site address
1 IONIC AVE
City
PARSIPPANY
State
NJ
ZIP
07054
Mailing
4931 NORTH 300 WEST, PROVO, UT 84604
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 7, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) worksite at 1 Ionic Ave Parsippany, NJ  Employees installing solar panels on a sloped residential roof surface, measured to be approximately 20 feet above ground level, were not provided with any means of fall protection.  Violation occurred on or about 11/19/2012.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 7, 2012
Penalty
Initial $5,000 · Current $5,000
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    a) work site at 1 Ionic Ave., Parsippany, NJ  Employees climbed a 20ft portable extension ladder to access residential roof that did not extend at least 3ft above landing.  Violation occurred on or about 11/19/2012.
Recent events (3)
  • — F (S) $5000
  • — C (S) $5000
  • — Z (S) $5000

View Vivint Solar INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337584411.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.