Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ICON BUILDERS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ICON BUILDERS, LLC in 2101 CHURCH ST., GALVESTON, TX 77550 (NAICS 236116). OSHA activity number 337584619.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Icon Builders, LLC — free Get an email when a new federal OSHA severe-injury report for Icon Builders, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ICON BUILDERS, LLC
Site address
2101 CHURCH ST.
City
GALVESTON
State
TX
ZIP
77550
Mailing
P.O. BOX 1363, NEDERLAND, TX 77627
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
15
Ownership type
A

4 citations on file for this inspection.

1926.405 A02 II E

Deleted Serious Gravity 5 3 instances 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 9, 2013
Penalty
Initial $2,400 · Current $0 Reduced
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    a) At the worksite and on the first floor of the apartment building, temporary lights strung for illumination were not protected against accidental contact or breakage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2400

1926.405 G01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 7, 2013
Abate by
Feb 9, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.405(g)(1)(ii): Flexible cord was not equipped with an attachment plug and energized from a receptacle outlet when used as permitted in 29 CFR 1926.405(g)(1)(i) [C], [F], or [H]:    a) At the worksite and on November 28, 2012, the attachment plug of a flexible cord was cut off and the conductors hard wired (bootlegged) to a stand of temporary lights that did were not energized from a receptacle outlet.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1926.150 A04

Other-than-serious 1 instance 3 exposed
Issued
Feb 7, 2013
Abate by
Feb 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.150(a)(4): Firefighting equipment was not periodically inspected:    a)  At the worksite and on November 28, 2012, a portable fire extinguisher, located on the second floor hallway, had not been inspected on a periodic basis.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.501 B04 II

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2013
Abate by
Feb 10, 2013
Penalty
Initial $400 · Current $400
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers:    a) At the worksite and on November 28, 2012, employees were not protected from stepping into holes at a third floor doorway threshold, due to the lack of covers.
Recent events (2)
  • — I (O) $400
  • — Z (O) $400

View Icon Builders, LLC's full OSHA safety record →