PELHAM, AL —
OSHA Inspection: PROCESS EQUIPMENT, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PROCESS EQUIPMENT, INC. in 2770 WELBORN STREET, PELHAM, AL 35124 (NAICS 333411). OSHA activity number 337593412.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROCESS EQUIPMENT, INC.
- Site address
- 2770 WELBORN STREET
- City
- PELHAM
- State
- AL
- ZIP
- 35124
- Mailing
- P.O. BOX 1607, PELHAM, AL 35124
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333411
- Employees
- 85
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Dec 17, 2012
- Penalty
- Initial $4,208 · Current $2,525 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: (a) On or about 11/27/2012 - Welding area, hoses where laying on the floor.
Recent events (2)
- — I (S) $2524.8
- — Z (S) $4208
1910.215 A04
- Issued
- Dec 17, 2012
- Penalty
- Initial $3,366 · Current $2,020 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about 11/27/2012 - Production area, the Big Grinder 102796 had the work rest adjusted to within 1/2 inch of the wheel.
Recent events (2)
- — I (S) $2019.6
- — Z (S) $3366
1910.303 F02
- Issued
- Dec 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) On or about 11/27/2012 - Production area, circuits supplying power to the water heater and lights to the restroom were not identified.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Dec 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about 11/27/2012 - Production area, a 220-volt electrical circuit breaker panel was blocked by pallets.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Dec 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about 11/27/2012 - Production area, unused opening at location #18, in the 220-Volt circuit panel was not effectively closed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Process Equipment, INC.
View Process Equipment, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333411)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337593412.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.