BRIDGEVIEW, IL —
OSHA Inspection: MICRON METAL FINISHING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MICRON METAL FINISHING in 8585 77TH AVENUE, BRIDGEVIEW, IL 60455 (NAICS 332812). OSHA activity number 337609416.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MICRON METAL FINISHING
- Site address
- 8585 77TH AVENUE
- City
- BRIDGEVIEW
- State
- IL
- ZIP
- 60455
- Mailing
- 8585 77TH AVENUE, BRIDGEVIEW, IL 60455
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 50
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 23, 2013
- Abate by
- Apr 23, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees a. Line 1 Dry Cure Ovens - On or about November 16, 2012, the employer did not ensure that the e-stop provided on the bake oven switchboard panel was operational prior to its use. Employees were thereby exposed to the hazards of live electrical parts.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.305 D01
- Issued
- Apr 23, 2013
- Abate by
- Apr 23, 2013
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(d)(1): Switchboards with exposed live parts. Switchboards that have any exposed live parts shall be located in permanently dry locations and shall be accessible only to qualified persons. a. Line #1 Dry Cure Ovens - On or about November 16, 2012, unqualified employees were required to access the bake oven switchboard panel thereby exposing them to the hazards of live electrical parts.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.23 C03
- Issued
- Apr 23, 2013
- Abate by
- Apr 23, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board. a. Hook set up area - On or about November 16, 2012, an employee was required to work on an open sided platform adjacent to a moving conveyor hook line. The conveyor hook line platform was not provided with a standard guard railing thereby exposing employees to hazards of moving parts.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.178 L02 II
- Issued
- Apr 23, 2013
- Abate by
- May 17, 2013
- Penalty
- Initial $2,800 · Current $200 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a. Entire Facility - On or about November 16, 2012, employees were required to operate powered industrial vehicles. The employees' training did not include practical exercises and/or an evaluation of the operators' performance.
Recent events (2)
- — I (O) $200
- — Z (S) $2800
1910.147 C04 II
- Issued
- Apr 23, 2013
- Abate by
- Jun 10, 2013
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section. a. Facility - On or about November 16, 2012, the following specific lockout/tagout procedures were not adequately developed to identify all energy sources and techniques to be utilized for the control of hazardous energy. 1. The line #1 dry and cure oven procedure did not identify a natural gas energy source. 2. The line #1 dry and cure oven procedure did not identify techniques for affixing multiple lockout devices when servicing operations took place.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C06 I
- Issued
- Apr 23, 2013
- Abate by
- Jun 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. Entire facility - On or about November 16, 2012, the employer had not conducted periodic inspections of established energy control procedures in place for employees who perform servicing and maintenance on such equipment including, but not limited to, the line dry cure ovens. Employees were thereby exposed to the hazards associated with the unexpected energization of equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Micron Metal Finishing
View Micron Metal Finishing's full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337609416.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.