Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VITAL STEEL ERECTORS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of VITAL STEEL ERECTORS in 4660 S. SAM HOUSTON PARKWAY EAST, HOUSTON, TX 77048 (NAICS 238210). OSHA activity number 337610422.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vital Steel Erectors — free Get an email when a new federal OSHA severe-injury report for Vital Steel Erectors is published. One employer, no account, unsubscribe in one click.
Site address
4660 S. SAM HOUSTON PARKWAY EAST
City
HOUSTON
State
TX
ZIP
77048
Mailing
5431 BROOKFIELD DRIVE, HOUSTON, TX 77045
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
45
Ownership type
A

3 citations on file for this inspection.

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 28, 2013
Penalty
Initial $2,618 · Current $2,000 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures were not  permanent and continuous.    North side of steel erected structure; employees used a yellow/blue flexible cord that was missing a ground prong to power DeWalt portable drill, model DW268, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2618

1926.405 G02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 28, 2013
Penalty
Initial $2,618 · Current $2,255 Reduced
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords were not connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    North side of steel erected structure; an employee used a red flexible cord that was pulled away from the strain relief to power DeWalt drill, model DW268, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $2255
  • — Z (S) $2618

1926.453 B02 V

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 28, 2013
Penalty
Initial $3,273 · Current $0 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift.     Near the center of steel erected structure; employees worked from a Genie lift, model S-45, without the use of fall protection, exposing the employee to fall hazards of approximately 43 feet
Recent events (2)
  • — I (S) $0
  • — Z (S) $3273

View Vital Steel Erectors's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337610422.