DES PLAINES, IL —
OSHA Inspection: NU-WAVE ELECTRIC, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NU-WAVE ELECTRIC, INC. in 1590 LEE ST., DES PLAINES, IL 60018 (NAICS 238210). OSHA activity number 337636021.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NU-WAVE ELECTRIC, INC.
- Site address
- 1590 LEE ST.
- City
- DES PLAINES
- State
- IL
- ZIP
- 60018
- Mailing
- 769 HEARTLAND DR. UNIT B, SUGAR GROVE, IL 60554
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 L04 III
- Issued
- Dec 18, 2012
- Abate by
- Feb 6, 2013
- Penalty
- Initial $1,360 · Current $952 Reduced
General-duty citation text
29 CFR 1926.602(d): Note: The requirements applicable to construction work under this paragraph are identical to those set forth at 1910.178(l) of this chapter. 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. a) The employer did not ensure that the employee operating the Pettibone Model B-66-D Extendo all-terrain forklift was evaluated once every three years. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $952
- — Z (S) $1360
1926.602 C01 II
- Issued
- Dec 18, 2012
- Abate by
- Dec 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.602(c)(1)(ii): Modifications or additions affecting the safe operation of the equipment were made without the manufacturer's written approval: Note: If such modifications or changes were made, the capacity, operation, and maintenance instruction plates, tags, or decals should have been changed accordingly. a) Employees were using Pettibone Model B966-D Extendo all terrain forklift to hoist and transport metal light posts suspended from the forks by the use of synthetic slings. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.251 A02 I
- Issued
- Dec 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.251(a)(2)(i): Employers did not ensure that rigging equipment had permanently affixed and legible identification markings as prescribed by the manufacturer that indicate the recommended safe working load; a) Employees were using a synthetic sling that did not have permanently affixed and legible identification markings. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Nu-Wave Electric, INC.
View Nu-Wave Electric, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337636021.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.