OSHA Inspection: LOBAR INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LOBAR INC. in SCHAEFFER LANE, KUTZTOWN, PA 19530 (NAICS 236220). OSHA activity number 337640015.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lobar INC. — free Get an email when a new federal OSHA severe-injury report for Lobar INC. is published. One employer, no account, unsubscribe in one click.
Establishment
LOBAR INC.
Site address
SCHAEFFER LANE
City
KUTZTOWN
State
PA
ZIP
19530
Mailing
ONE OLD MILL ROAD, DILLSBURG, PA 17019
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.403 I02 I

Other-than-serious 2 instances 4 exposed
Issued
Jan 14, 2013
Abate by
Feb 8, 2013
Penalty
Initial $4,500 · Current $4,500
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.    (a) Sound Booth, Back of Auditorium -  Romex temporary power cords were spliced with wire nuts and wrapped with electrical tape at two temporary power pedestal stands.  Employees and other contractors plugged tools and devices into the temporary power pedestal stands and were exposed to electric shock hazards on or about November 21, 2012.    (b) Basement hallway east end -  Romex temporary power cords were spliced with wire nuts and wrapped with electrical tape at a temporary power pedestal stand.  Employees and other contractors plugged tools and devices into the temporary power pedestal stand and were exposed to electric shock hazards on or about November 21, 2012.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $4500
  • — Z (S) $4500

1926.502 B02 I

Other-than-serious 1 instance 5 exposed
Issued
Jan 14, 2013
Penalty
Initial $4,500 · Current $4,500
29 CFR 1926.502(b)(2)(i): Midrails, when used, were not installed at a height midway between the top edge of the guardrail system and the walking/working level.     (a) Schaeffer Auditorium, Kutztown University - The employer did not ensure that the 3/8 inch wire rope midrail which protected the edge of the first floor storeroom, behind the stage, was secured in place by approved clamps.  The midrail was slack and masonry subcontractors were exposed to a fall of approximately 14 feet to the ground below on or about November 21, 2012.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $4500
  • — Z (S) $4500