Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PACIFIC NORTHWEST FARMERS COOPERATIVE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PACIFIC NORTHWEST FARMERS COOPERATIVE, INC. in 117 WEST CHESTNUT STREET, GENESEE, ID 83832 (NAICS 424510). OSHA activity number 337640213.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pacific Northwest Farmers Cooperative, INC. — free Get an email when a new federal OSHA severe-injury report for Pacific Northwest Farmers Cooperative, INC. is published. One employer, no account, unsubscribe in one click.
Site address
117 WEST CHESTNUT STREET
City
GENESEE
State
ID
ZIP
83832
Mailing
P.O. BOX 67, GENESEE, ID 83832
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
8
Ownership type
A

9 citations on file for this inspection.

1910.27 D01 II

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Mar 21, 2013
Abate by
Apr 16, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.27(d)(1)(ii):     Cages or wells (except as provided in subparagraph (5) of this paragraph) conforming to the dimensions shown in figures D-7, D-8, and D-9 were not provided on ladders of more than 20 feet to a maximum unbroken length of 30 feet.     a) West End Steel Tank # 4; On or about November 27, 2012 and at times prior thereto, employees were exposed to a 84.5 foot fall from a fixed ladder that provides access to the elevator head/gallery and tank top.    b) East end square building Pit 2; On or about November 27, 2012 and at times prior thereto, employees were exposed to a 110 foot  fall from a fixed ladder that provides access to the elevator head /gallery and top of building.     Note: Abatement certification IS required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.272 J02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 21, 2013
Abate by
Apr 16, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.272(j)(2)(ii):     The employer did not immediately remove any fugitive grain dust accumulations whenever they exceed 1/8 inch (.32 cm) at priority housekeeping areas, pursuant to the housekeeping program, or shall demonstrate and assure, through the development and implementation of the housekeeping program, that equivalent protection is provided.    a)   At the East End new building between bins 9 & 10 at the scale; On or about, November 27, 2012 and at times prior thereto, the employer allowed fugitive grain dust, a fire hazard, to accumulate to a depth of 1 inch on the scale and areas adjacent to it.    Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1910.272 K

Other-than-serious 1 instance 8 exposed
Issued
Mar 21, 2013
Abate by
Apr 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.272(k):     Receiving-pit feed openings, such as truck or railcar receiving-pits, were covered by grates. The widths of openings in the grates were greater than the maximum of 2 1/2 inches (6.35 cm).     a) At the East End Square building, east end receiving pit near bins 5,6,& 27; On or about November 27, 2012, and at times prior thereto, the grates covering the receiving pits had gaps up to 3 1/2 inches.     Note; Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling.     a) At the East End new building, between Bins 9 & 10 at the scale/ work room; On or about November 27, 2012, and at times prior thereto, the re-locatable power tap was plugged into another re-locatable power tap to provide power for a lamp.     Note: Abatement certification is NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 A02 IX

Other-than-serious 1 instance 3 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ix):     All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard:     a) At the East End new building, between Bins 9 & 10 at the scale/ work room; On or about November 27, 2012, and at times prior thereto, the incandescent light over the work bench and within arms length was not protected.     Note: Abatement certification is NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 3 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):     Unused openings in cabinets, boxes, and fittings were not effectively closed;    a) At the West End Steel Tanks and concrete tubes Pit control room; On or about November 27, 2012, and at times prior thereto, the circuit breaker panel had an open breaker slot / missing a breaker.     Note: Abatement certification is NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 2 instances 3 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose:    a) At the West end Square Building pit control room, by west tank 1; On or about November 27, 2012 and at times prior thereto, the junction box was missing its cover.     b) At the West end Square Building pit control room; On or about November 27, 2012 and at times prior thereto, the horizontal electrical box was missing its cover.    Note: Abatement certification is NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 6 exposed
Issued
Mar 21, 2013
Abate by
Apr 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and cables were used as a substitute for the fixed wiring of a structure;     a) East End steel tanks Pit between Tanks 2 & 3; On or about November 27, 2012, and at times prior thereto, extension cord were used to supply power to an explosion proof light.    Note; Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV B

Other-than-serious 1 instance 3 exposed
Issued
Mar 21, 2013
Abate by
Apr 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B):     Flexible cords and cables were run through holes in walls, ceilings, or floors;     a) West End Square building control room; On or about November 27, 2012, and at times prior thereto, flexible cords were passed through a wall and used to supply power to a winch and a seed treater.    Note; Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Pacific Northwest Farmers Cooperative, INC.'s full OSHA safety record →