BEDFORD, MA —
OSHA Inspection: NATION WIDE BUILDER, INC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of NATION WIDE BUILDER, INC in 350 CONCORD ROAD, BEDFORD, MA 01730 (NAICS 238320). OSHA activity number 337666812.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATION WIDE BUILDER, INC
- Site address
- 350 CONCORD ROAD
- City
- BEDFORD
- State
- MA
- ZIP
- 01730
- Mailing
- 16 JAMES STREET , APT 2, MALDEN, MA 02148
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 G01 VII
- Issued
- Jan 30, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location - 350 Concord Road, Bedford, MA: On or about 11/29/2012, an employee working from a roof bracket scaffold was not protected from falling to the ground below while at a height greater than ten feet above a lower level.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Jan 30, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access. Location - 350 Concord Road, Bedford, MA: On or about 11/29/2012, an employee accessing a roof bracket scaffold was using an extension ladder that did not extend three feet beyond the scaffold plank in which the employee was accessing.
Recent events (1)
- — Z (S) $2800
More inspections in this industry (NAICS 238320)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337666812.