OSHA Inspection: ADVANCE WAREHOUSING & DISTRIBUTION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ADVANCE WAREHOUSING & DISTRIBUTION in 33 MCWHIRTER ROAD, KEARNY, NJ 07032 (NAICS 493110). OSHA activity number 337670038.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advance Warehousing & Distribution — free Get an email when a new federal OSHA severe-injury report for Advance Warehousing & Distribution is published. One employer, no account, unsubscribe in one click.
Site address
33 MCWHIRTER ROAD
City
KEARNY
State
NJ
ZIP
07032
Mailing
33 MCWHIRTER ROAD, KEARNY, NJ 07032
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
25
Ownership type
A

9 citations on file for this inspection.

1910.178 Q01

Serious Gravity 10 4 instances 1 exposed
Issued
Apr 19, 2013
Abate by
Jun 6, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  a) Toyota Model 5FGC15 propane forklift, S/N 71079  A forklift used inside the warehouse was not in safe operating condition:  it had a broken tank clamp, damaged seat belt and discharged 900 parts per million (ppm) carbon monoxide in its exhaust.  Violation occurred on or about 12/6/12.   b) Toyota Model 5FGC15 propane forklift, S/N 72155   A forklift used inside the warehouse was not in safe operating condition:  it had two broken rear lights and discharged at least 2000 ppm carbon monoxide it its exhaust.  Violation occurred on or about 12/6/12.   c) Toyota Model 5FGC15 propane forklift, S/N 72687  A forklift used inside the warehouse was not in safe operating condition:  It had a damaged, inoperable seat belt and discharged at least at least 2000 ppm carbon monoxide in its exhaust.  Violation occurred on or about 12/6/12.   d)  Clark Model CGC25 propane forklift, S/N C3656-0077-9452FB   A forklift used inside the warehouse was not in safe operating condition:  It had a broken load backrest and discharged 1500 ppm carbon monoxide in its exhaust.  Violation occurred on or about 12/6/12.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.178 Q07

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 19, 2013
Abate by
May 15, 2013
Penalty
Initial $2,400 · Current $1,800 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:   a) Establishment   Electric and propane powered forklifts used at the facility were not inspected daily for conditions adversely affecting vehicle safety before being placed in service.  Only water, oil and battery charge were checked.  Violation occurred on or about 12/6/12.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2400

1910.303 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 19, 2013
Abate by
May 1, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:   a) Warehouse, south wall, shipping and receiving  Access to a circuit panel with breakers for lights and office was obstructed by cords and equipment on the floor.  Violation occurred on or about 12/4/12.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 19, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) Warehouse, south wall, shipping and receiving    A circuit panel with breakers for lights and the office was uncovered, exposing wiring with 480 V.    Violation occurred on or about 12/6/12.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.1000 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 19, 2013
Abate by
Jun 6, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of carbon monoxide listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 50 parts per million (ppm):    a) Warehouse    Three employees were exposed to carbon monoxide at levels of 85 ppm, 257 ppm and 375 ppm as an 8 hour Time Weighted Average, which were 1.7, 4.9 and 7.5 times the OSHA Permissible Exposure Limit of 50 ppm, respectively.  Exposure periods were 345, 440 and 435 minutes, respectively.  Exposures were calculated from the percent carboxyhemoglobin in the blood and other factors such as atmospheric pressure, height, weight, activity levels and tobacco smoking.  Zero exposure was assumed for 135, 40 and 45 minutes, respectively, outside the exposure period.    Violation occurred on or about 12/4/12.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.1000 E

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 19, 2013
Abate by
Jun 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a) Warehouse  Four propane forklifts were used to pick and move goods inside an unventilated warehouse.  Three employees were exposed to carbon monoxide at levels of 85 ppm, 257 ppm and 375 ppm as an 8 hour Time Weighted Average, which were 1.7, 4.9 and 7.5 times the OSHA Permissible Exposure Limit of 50 ppm, respectively.  Exposure periods were 345, 440 and 435 minutes, respectively.  Exposures were calculated from the percent carboxyhemoglobin in the blood and other factors such as atmospheric pressure, height, weight, activity levels and tobacco smoking.   Zero exposure was assumed for 135, 40 and 45 minutes, respectively, outside the exposure period.   Violation occurred on or about 12/4/12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 19, 2013
Abate by
Jun 6, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which described how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) would be met.  a) Establishment  The employer did not develop and implement a written hazard communication program for warehouse employees working with hazardous substances including, but not limited to, propane, lead acid batteries and forklift exhaust which contains carbon monoxide.  Violation occurred on or about 12/4/12.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.1200 G08

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 19, 2013
Abate by
Jun 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace:  a) Establishment  The employer did not have material safety data sheets for hazardous substances in the workplace including, but not limited to, propane and lead acid batteries.  Violation occurred on or about 12/4/12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 19, 2013
Abate by
Jun 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area:  a) Establishment  The employer did not train warehouse employees working with hazardous substances including, but not limited to, propane, lead acid batteries and forklift exhaust which contained carbon monoxide.  Violation occurred on or about 12/4/12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337670038.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.