Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INNOVISION LED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INNOVISION LED in 979 NORTHAMPTON STREET, BUFFALO, NY 14211 (NAICS 339950). OSHA activity number 337675821.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Innovision LED — free Get an email when a new federal OSHA severe-injury report for Innovision LED is published. One employer, no account, unsubscribe in one click.
Establishment
INNOVISION LED
Site address
979 NORTHAMPTON STREET
City
BUFFALO
State
NY
ZIP
14211
Mailing
979 NORTHAMPTON STREET, BUFFALO, NY 14211
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
12
Ownership type
A

7 citations on file for this inspection.

1910.24 H

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.24(h):     Standard railings were not provided on the open sides of all exposed stairways and stair platforms:    a) On or about 12/11/2012 in the assembly area - where there was no railing on the open side of the stairway to the upstairs assembly area.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.36 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 4, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.36(d)(1):     A required exit(s), way of approach thereto, and/or way of travel from the exit into the street or open space, was not continuously maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency:    a) On or about 12/11/2012 in the metal fabrication room; where the exit door was locked in the closed position with three sliding bolt locks (top, middle and bottom).    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.106 E02 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.106(e)(2)(iv)(a):     Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 F (37.8 C), were not kept in covered containers when not actually in use:    a) On or about 12/11/2012 in the paint room - where there was an open, uncovered 5 gallon pail of solvent.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.107 C06

Other-than-serious 1 instance 2 exposed
Issued
Feb 4, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.107(c)(6):     Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    a) On or about 12/11/2012 in the paint room - where standard duty electrical equipment including, but not limited to: switches, lighting and motors, was installed in the area where spray finishing of flammable coatings was performed.    ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) On or about 12/11/2012 in the fabrication area - where the table saw used for cutting metal and plastic was not provided with a guard for the saw blade.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) On or about 12/11/2012 in the metal fabrication room - where a metal duplex receptacle box at the end of a flexible cord was used as an extension cord. The metal box was not securely mounted as required by the National Electrical Code.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 4, 2013
Abate by
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(g)(2)(i):     Live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) On or about 12/11/2012 in the router operations room - where the electrical panel for the heater and receptacles was missing the front cover, exposing employees to "live" electrical parts.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337675821.