Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: 3D BODY WORKS INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of 3D BODY WORKS INC in 300 W BOOT ROAD, WEST BRADFORD, PA 19380 (NAICS 811111). OSHA activity number 337699847.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 3D Body Works INC — free Get an email when a new federal OSHA severe-injury report for 3D Body Works INC is published. One employer, no account, unsubscribe in one click.
Establishment
3D BODY WORKS INC
Site address
300 W BOOT ROAD
City
WEST BRADFORD
State
PA
ZIP
19380
Mailing
300 W BOOT ROAD, WEST CHESTER, PA 19380
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.101 B

Serious Gravity 1 3 instances 3 exposed
Issued
Mar 20, 2013
Abate by
Apr 8, 2013
Penalty
Initial $2,100 · Current $2,100
29 CFR 1910.101(b):     "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6.    a) 3D Works Inc. - Employees were exposed to fire and struck by hazards from the employer improperly storing empty  fuel cylinders [e.g propane cylinders] at the entrance of a storage facility. The employer had stored the propane cylinders with gasoline [e.g. See Section 3.3.6 of CGA pamphlet] in the storage building.  This was observed on December 6, 2012.
Recent events (1)
  • — Z (S) $2100

1910.102 A

Serious Gravity 1 2 instances 15 exposed
Issued
Mar 20, 2013
Abate by
Apr 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.102(a):     Cylinders. Employers must ensure that the in-plant transfer, handling, storage, and use of acetylene in cylinders comply with the provisions of CGA Pamphlet G-1-2009 ("Acetylene") (Compressed Gas Association, Inc., 12th ed., 2009).    a) 3D Body Works Inc. - The employer improperly stored oxygen and acetylene fuel cylinders adjacent to one another in the storage building [e.g. See Section 5.2 of the CGA Pamphet]. This was observed on December 6, 2012.
Recent events (1)
  • — Z (S) $0

1910.106 D05 VI A

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 20, 2013
Abate by
Apr 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(5)(vi)(a):     When the storage building was located 50 feet (15.2 m) or less from a building or line of adjoining property that could  be built upon, the exposing wall was not a blank wall having a fire-resistance rating of at least 2 hours;    a) 3D Works Inc./300 W. Boot Road - The employer improperly constructed, a 4 x 8 foot wooden storage building within 50 feet from the body shop. This storage facility improperly houses fuel gases [e.g. propane and Acetylene] and 55 gallon drums of residual flammable liquids and oxygen cylinders. This was observed on December 6, 2012.
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 3 instances 3 exposed
Issued
Mar 20, 2013
Penalty
Initial $2,100 · Current $2,100
29 CFR 1910.134(f)(2):     The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.    a) 3D Body Works Inc. - The employer provided and required employees performing sanding and welding operations to wear 3M model, elastomeric, air purifying respirators. The employer did not perform annual fit testing of their employees in accordance with this section of the standard. This was observed on December 6, 2012.
Recent events (1)
  • — Z (S) $2100

1910.242 B

Serious Gravity 1 2 instances 5 exposed
Issued
Mar 20, 2013
Penalty
Initial $2,100 · Current $2,100
29 CFR 1910.242(b):     Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.    a) 3D Body Works Inc. - Several Employees are exposed to eye injuries and/or skin embolism when operating compressed air nozzles. Employees were operating the equipment to clean the surfaces of the work benches and themselves.   The nozzles being operated were releasing a stream of air pressure at approximately 40 P.S.I. The air nozzles are attached to regulators that can be adjusted by the employees associated with the painting and/or sanding operations. This was observed on December 6, 2012.
Recent events (1)
  • — Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337699847.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.