OSHA Inspection: ANTONIO JOSE CAGUANA DBA CAGUANA'S CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANTONIO JOSE CAGUANA DBA CAGUANA'S CONSTRUCTION, INC. in 653 BLACKSTONE, HIGHLAND PARK, IL 60035 (NAICS 238160). OSHA activity number 337746010.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Antonio Jose Caguana DBA Caguana'S Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Antonio Jose Caguana DBA Caguana'S Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
653 BLACKSTONE
City
HIGHLAND PARK
State
IL
ZIP
60035
Mailing
3337 W. CULLOM, CHICAGO, IL 60618
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

7 citations on file for this inspection.

1926.452 M01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Dec 24, 2012
Penalty
Initial $2,800 · Current $1,200 Reduced
29 CFR 1926.452(m)(1): Crawling boards did not extend from the roof peak to the eaves when used in connection with roof construction, repair, or maintenance:    a) Ladders used a crawling boards ("chicken" ladders) did not extend from the roof peak to the eave when used during roofing work.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2800

1926.452 M02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Dec 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.452(m)(2): Crawling boards were not secured to the roof by ridge hooks or by means that meet equivalent criteria (e.g., strength and durability):    a) Ladders used as crawling boards ("chicken" ladders) were not secured to the roof by ridge hooks or by other equivalent means.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 7 instances 7 exposed
Issued
Dec 18, 2012
Abate by
Dec 24, 2012
Penalty
Initial $2,800 · Current $1,200 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a) Employees were not protected from the hazard of falling while performing roofing work on a roof having a pitch of approximately 10/12 and a ground to eave height of approximately 12 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2800

1926.502 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Dec 24, 2012
Penalty
Initial $2,800 · Current $1,200 Reduced
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:    a) a) The connection of personal fall arrest equipment worn by an employee working from the roof consisted of a synthetic rope that had been knotted/tied to the dee-ring of a harness.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2800

1926.502 D15 II

Serious Gravity 10 2 instances 2 exposed
Issued
Dec 18, 2012
Abate by
Dec 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment were not designed, installed and used under the supervision of a qualified person:    a) Anchorages used for the attachment of personal fall arrest equipment used during roofing work on the front and rear elevations of the building were not designed, installed and used under the supervision of a qualified person.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Dec 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    a) Personal fall arrest equipment was not rigged to prevent employees from being exposed to the hazard of free falling more than 6 feet and contacting a lower level while performing roofing work.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 9 instances 9 exposed
Issued
Dec 18, 2012
Abate by
Jan 15, 2013
Penalty
Initial $2,000 · Current $600 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    a) The employer did not provide training to enable employees to recognize the hazards of falling and the procedures to be followed to eliminate or control such hazards at the worksite.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).