1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: BEN HILL ROOFING AND SIDING CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BEN HILL ROOFING AND SIDING CO., INC. in 1030 MAIN ST. HIGHWAY 431, WEDOWEE, AL 36278 (NAICS 238160). OSHA activity number 337747018.

Watch BEN Hill Roofing AND Siding CO., INC. — free Get an email when a new federal OSHA severe-injury report for BEN Hill Roofing AND Siding CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1030 MAIN ST. HIGHWAY 431
City
WEDOWEE
State
AL
ZIP
36278
Mailing
6811 WEST BANKHEAD HIGHWAY, DOUGLASVILLE, GA 30134
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
42
Ownership type
A

4 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2450.00 Reduced
29 CFR 1926.501(b)(10):     Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    a) On or about December 6, 2012 - 1030 Main St, Wedowee, AL, Employees working 32 feet above the ground were not provided fall protection while installing roofing materials.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3570.00 · Current $1785.00 Reduced
29 CFR 1926.1053(b)(1):     Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a) On or about December 6, 2012 - 1030 Main St, Wedowee, AL,  an 8 foot aluminum step ladder being used by employees did not extend 3 feet above the roof.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $3570

1926.1053 B04

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4):     Ladder(s) were used for purposes other than the purpose for which they were designed:    a) On or about December 6, 2012 - 1030 Main St, Wedowee, AL, an 8 foot aluminum stepladder was used in the closed position to access an upper landing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B05 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(5)(i):     Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder:    a) On or about December 6, 2012 - 1030 Main St, Wedowee, AL,an 8 foot aluminum stepladder was not used in the closed position and did not meet the proper angle.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View BEN HILL ROOFING AND SIDING CO., INC.'s full OSHA safety record →