Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUILDINGS ETCETERA

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BUILDINGS ETCETERA in 108 NORTH ST, HOULTON, ME 04730 (NAICS 238130). OSHA activity number 337755219.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Buildings Etcetera — free Get an email when a new federal OSHA severe-injury report for Buildings Etcetera is published. One employer, no account, unsubscribe in one click.
Establishment
BUILDINGS ETCETERA
Site address
108 NORTH ST
City
HOULTON
State
ME
ZIP
04730
Mailing
P.O. BOX 949, HOULTON, ME 04730
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.304 F

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 26, 2012
Abate by
Jan 4, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1926.304(f):    Section 3.1.3(c): American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  On applications where injury to the operator might result if motors were to restart after power failures, provision was not made to prevent machines from automatically restarting upon restoration of power:    Worksite - The Rockwell 10" table saw did not have an anti-restart device:
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 26, 2012
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.404(b)(1)(ii):    Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection.     Worksite - The compound miter saw on the orange extension cord did not have approved ground fault circuit interrupter protection.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.403 I02 I

Serious Gravity 5 2 instances 6 exposed
Issued
Dec 26, 2012
Abate by
Jan 2, 2013
Penalty
Initial $2,400 · Current $1,680 Reduced
29 CFR 1926.403(i)(2)(i):    Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means listed in subparagraphs (A) through (D) of this paragraph:     Utilities Room - The energized two main breaker panels were missing the panel covers.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2400

View Buildings Etcetera's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337755219.