Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUNNINGHAM CABINETS LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CUNNINGHAM CABINETS LTD. in 1911 KALANI ST., HONOLULU, HI 96819 (NAICS 337110). OSHA activity number 337757215.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cunningham Cabinets LTD. — free Get an email when a new federal OSHA severe-injury report for Cunningham Cabinets LTD. is published. One employer, no account, unsubscribe in one click.
Site address
1911 KALANI ST.
City
HONOLULU
State
HI
ZIP
96819
Mailing
1911 KALANI ST., HONOLULU, HI 96819
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
20
Ownership type
A

8 citations on file for this inspection.

1910.213 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 13, 2012
Abate by
Jan 17, 2013
Penalty
Initial $1,700 · Current $1,275 Reduced
29 CFR 1910.213(d)(1):     Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  a) Mill Area: The Altendorf table saw was not equipped with an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut, as observed on or about December 10, 2012.  Abatement Certification Required
Recent events (2)
  • — I (S) $1275
  • — Z (S) $1700

1910.213 J03

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 13, 2012
Abate by
Jan 17, 2013
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1910.213(j)(3):     Hand-fed jointer(s) with horizontal cutting head(s) did not have automatic guard(s) which automatically adjusted to cover the unused portion of the head and/or remained in contact with the material at all times:  a) Mill Area: The blade guard on the Grizzly jointer did not automatically adjust to cover the unused portion of the cutting head and/or remain in contact with the material at all times, as observed on or about Decemner 10, 2012.  Abatement Certification Required.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1020

1910.213 P04

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 13, 2012
Abate by
Jan 17, 2013
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1910.213(p)(4):     Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points:  a) Mill Area: The belt sander was not equipped with guards at each nip point where the sanding belt ran on the pulleys, as observed on or about December 10, 2012.  Abatement Certification Required.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1020

1910.303 G02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 13, 2012
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) Mill Area: The cover for the electrical box on the belt sander was missing exposing the energized conductors to contact, as observed on or about December 10, 2012.  Abatement Observed During Inspection
Recent events (2)
  • — I (S) $765
  • — Z (S) $1020

1910.305 B01 I

Serious Gravity 1 4 instances 1 exposed
Issued
Dec 13, 2012
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i):     Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:  a) Main Shop: Energized conductors entering an electrical junction box attached to the scissor lift operating pedal were not protected from abrasion, as observed on or about December 10, 2012.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II

Other-than-serious 4 instances 1 exposed
Issued
Dec 13, 2012
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii):     Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  a) Main Shop: The employer did not have specific procedures for the control of hazardous energy to equipment including, but not limited to, CNC routers, panel saw and edge bander, on or about December 10, 2012.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Dec 13, 2012
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Main Shop: The employer did not conduct a periodic inspection of the energy control procedure at least annually, on or about December 10, 2012.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Dec 13, 2012
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a) Main Shop: A compressed air wand, located near the CNC router, was not equipped with a safety tip to reduce the compressed air to less than 30 PSI, as observed on or about December 10, 2012.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cunningham Cabinets LTD.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337757215.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.