HONOLULU, HI —
OSHA Inspection: CUNNINGHAM CABINETS LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CUNNINGHAM CABINETS LTD. in 1911 KALANI ST., HONOLULU, HI 96819 (NAICS 337110). OSHA activity number 337757215.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUNNINGHAM CABINETS LTD.
- Site address
- 1911 KALANI ST.
- City
- HONOLULU
- State
- HI
- ZIP
- 96819
- Mailing
- 1911 KALANI ST., HONOLULU, HI 96819
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 20
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.213 D01
- Issued
- Dec 13, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $1,700 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Mill Area: The Altendorf table saw was not equipped with an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut, as observed on or about December 10, 2012. Abatement Certification Required
Recent events (2)
- — I (S) $1275
- — Z (S) $1700
1910.213 J03
- Issued
- Dec 13, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.213(j)(3): Hand-fed jointer(s) with horizontal cutting head(s) did not have automatic guard(s) which automatically adjusted to cover the unused portion of the head and/or remained in contact with the material at all times: a) Mill Area: The blade guard on the Grizzly jointer did not automatically adjust to cover the unused portion of the cutting head and/or remain in contact with the material at all times, as observed on or about Decemner 10, 2012. Abatement Certification Required.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.213 P04
- Issued
- Dec 13, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points: a) Mill Area: The belt sander was not equipped with guards at each nip point where the sanding belt ran on the pulleys, as observed on or about December 10, 2012. Abatement Certification Required.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.303 G02 I
- Issued
- Dec 13, 2012
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) Mill Area: The cover for the electrical box on the belt sander was missing exposing the energized conductors to contact, as observed on or about December 10, 2012. Abatement Observed During Inspection
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.305 B01 I
- Issued
- Dec 13, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) Main Shop: Energized conductors entering an electrical junction box attached to the scissor lift operating pedal were not protected from abrasion, as observed on or about December 10, 2012. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II
- Issued
- Dec 13, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Main Shop: The employer did not have specific procedures for the control of hazardous energy to equipment including, but not limited to, CNC routers, panel saw and edge bander, on or about December 10, 2012. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- Dec 13, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Main Shop: The employer did not conduct a periodic inspection of the energy control procedure at least annually, on or about December 10, 2012. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.242 B
- Issued
- Dec 13, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Main Shop: A compressed air wand, located near the CNC router, was not equipped with a safety tip to reduce the compressed air to less than 30 PSI, as observed on or about December 10, 2012. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cunningham Cabinets LTD.