Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MILONE ENTERPRISE INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MILONE ENTERPRISE INC in 990 GARAFOLO ROAD, WEYMOUTH, MA 02189 (NAICS 236118). OSHA activity number 337776819.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Milone Enterprise INC — free Get an email when a new federal OSHA severe-injury report for Milone Enterprise INC is published. One employer, no account, unsubscribe in one click.
Site address
990 GARAFOLO ROAD
City
WEYMOUTH
State
MA
ZIP
02189
Mailing
24 MUTTON LANE, WEYMOUTH, MA 02189
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.304 D

Serious Gravity 10 2 instances 4 exposed
Issued
Jan 29, 2013
Abate by
Feb 6, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.304(d):     Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.      Jobsite:  Crews were using two table saws on site to cut wood trim and wood siding with no guards in place exposing employees to cuts, lacerations and amputations.
Recent events (1)
  • — Z (S) $2800

1926.405 G02

Serious Gravity 5 2 instances 5 exposed
Issued
Jan 29, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.405(g)(2):     Identification, splices, and terminations -    Flexible cords shall be used only in continuous lenghts without splice or tap.  Hard sercive flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath  properties, and usage characteristics of the cord being spliced.    Jobsite:  Employees were using extension cords which had damaged femaile fittings and torn exposed wires that were covered with electrical tape exposed to the outdoor enviroment exposing employees to potential electrical shock.
Recent events (1)
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337776819.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.