LAFAYETTE, LA —
OSHA Inspection: AMERIGLOBE FIBC SOLUTIONS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERIGLOBE FIBC SOLUTIONS in 153 S. LONG ST., LAFAYETTE, LA 70506 (NAICS 326111). OSHA activity number 337829816.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERIGLOBE FIBC SOLUTIONS
- Site address
- 153 S. LONG ST.
- City
- LAFAYETTE
- State
- LA
- ZIP
- 70506
- Mailing
- 153 S. LONG ST., LAFAYETTE, LA 70506
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326111
- Employees
- 35
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 25, 2013
- Abate by
- Mar 1, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed and documented for the control of potentially hazardous energy when employees were engaged in activities covered by this section. The procedures shall clearly and specifically outline the means to enforce compliance including, but not limited to, the following: The employer did not develop written procedures with specific steps for the control of potentially hazardous energy regarding machines and equipment such as, but not limited to: a) Bay 1: Two bag press machines b) Bay 2: 1. Bag press machine 2. Scrap baler machine 3. Manual cutting machine c) Bay 3: Bag filling station
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.179 J03
- Issued
- Jan 25, 2013
- Abate by
- Mar 1, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.179(j)(3): Periodic inspection. Complete inspections of the crane shall be performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section, depending upon its activity, severity of service, and environment, or as specifically indicated below. These inspections shall include the requirements of paragraph (j)(2) of this section and in addition, the following items. Any deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard: The employer failed to ensure that overhead gantry cranes throughout the facility were periodically inspected: 1. Bay 1 - Two overhead gantry cranes 2. Bay 2 - One overhead gantry crane (Double compression unit) 3. Bay 3 - Two overhead gantry cranes 4. Bay 4 - One overhead gantry crane
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 B01 II
- Issued
- Jan 25, 2013
- Abate by
- Feb 20, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a) Bay 4, Panel K; an electrical panel did not have a blank or knockout to cover a circuit breaker opening, exposing employees to possible contact with live electrical conductors and the hazard of an electrical shock.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 B02 I
- Issued
- Jan 25, 2013
- Abate by
- Feb 13, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a) Wash Room; An electrical box did not have a cover. The wires inside the box were exposed and live. b) Packing department: 1. Glue Machine; an electrical box on front of the machine was missing the cover. The box had tape over the wires inside which were live. 2. Ventilator machine; faceplate of the wall switch was missing. This condition exposed employees to an electric shock hazard.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.303 F02
- Issued
- Jan 25, 2013
- Abate by
- Feb 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. a) Bay 1; electrical circuits in panel FPE were not labeled for its intended use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326111)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337829816.