BROOKLYN, NY —
OSHA Inspection: A&A MASONRY INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A&A MASONRY INC. in 456 MAYFAIR DR S, BROOKLYN, NY 11234 (NAICS 238140). OSHA activity number 337830228.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A&A MASONRY INC.
- Site address
- 456 MAYFAIR DR S
- City
- BROOKLYN
- State
- NY
- ZIP
- 11234
- Mailing
- 2472 MCDONALD AVE 2ND FL, BROOKLYN, NY 11223
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Jan 23, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. a) Front of Residence: On or about December 11, 2012 Employees were were exposed to falling brick while working on a masonry wall.
Recent events (3)
- — F (S) $600
- — C (S) $1200
- — Z (S) $1200
1926.404 B01 I
- Issued
- Jan 23, 2013
- Abate by
- Feb 6, 2013
- Penalty
- Initial $1,200 · Current $900 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. a) Front of Residence: On or about December 11, 2012 An employee used a mixer which was plugged in by extension cord. The extension cord was not protected by GFI.
Recent events (3)
- — F (S) $900
- — C (S) $1200
- — Z (S) $1200
1926.404 F06
- Issued
- Jan 23, 2013
- Abate by
- Feb 6, 2013
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a) Front of Residence: On or about December 11, 2012 An employee used a mixer which was plugged in by extension cord. The extension cord was missing the ground pin.
Recent events (3)
- — F (S) $0
- — C (S) $1200
- — Z (S) $1200
1926.451 B01
- Issued
- Jan 23, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $2,000 · Current $900 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: a) Front of Residence: On or about December 11, 2012 Employees were exposed to falls of 12 feet while working on the exterior masonry walls from a tubular welded frame scaffold 2 frames high which was not fully planked.
Recent events (3)
- — F (S) $900
- — C (S) $2000
- — Z (S) $2000
1926.451 C02
- Issued
- Jan 23, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a) Front of Residence: On or about December 11, 2012 Employees were exposed to falls of 12 feet while working on the exterior masonry walls from a tubular welded frame scaffold 2 frames high which was supported on unsafe mudsills in that masonry block was improperly stacked.
Recent events (3)
- — F (S) $0
- — C (S) $2000
- — Z (S) $2000
1926.451 G01 VII
- Issued
- Jan 23, 2013
- Abate by
- Jan 31, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Front of Residence: On or about December 11, 2012 Employees were exposed to falls of 12 feet while working on the exterior masonry walls from a tubular welded frame scaffold 2 frames high.
Recent events (3)
- — F (S) $0
- — C (S) $2000
- — Z (S) $2000
More inspections at A&A Masonry INC.
View A&A Masonry INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337830228.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.