OSHA Inspection: A&A MASONRY INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A&A MASONRY INC. in 456 MAYFAIR DR S, BROOKLYN, NY 11234 (NAICS 238140). OSHA activity number 337830228.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A&A Masonry INC. — free Get an email when a new federal OSHA severe-injury report for A&A Masonry INC. is published. One employer, no account, unsubscribe in one click.
Establishment
A&A MASONRY INC.
Site address
456 MAYFAIR DR S
City
BROOKLYN
State
NY
ZIP
11234
Mailing
2472 MCDONALD AVE 2ND FL, BROOKLYN, NY 11223
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 23, 2013
Abate by
Jan 31, 2013
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.100(a):     Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.      a)  Front of Residence:         On or about December 11, 2012              Employees were were exposed to falling brick while working on a masonry wall.
Recent events (3)
  • — F (S) $600
  • — C (S) $1200
  • — Z (S) $1200

1926.404 B01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 23, 2013
Abate by
Feb 6, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.404(b)(1)(i):     General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    a)  Front of Residence:         On or about December 11, 2012              An employee used a mixer which was plugged in by extension cord.  The extension cord was not protected by GFI.
Recent events (3)
  • — F (S) $900
  • — C (S) $1200
  • — Z (S) $1200

1926.404 F06

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 23, 2013
Abate by
Feb 6, 2013
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.404(f)(6):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    a)  Front of Residence:         On or about December 11, 2012              An employee used a mixer which was plugged in by extension cord.  The extension cord was missing the ground pin.
Recent events (3)
  • — F (S) $0
  • — C (S) $1200
  • — Z (S) $1200

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 23, 2013
Abate by
Jan 31, 2013
Penalty
Initial $2,000 · Current $900 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:      a)  Front of Residence:         On or about December 11, 2012              Employees were exposed to falls of 12 feet while working on the exterior masonry walls from a tubular welded frame scaffold 2 frames high which was not fully planked.
Recent events (3)
  • — F (S) $900
  • — C (S) $2000
  • — Z (S) $2000

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 23, 2013
Abate by
Jan 31, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.    a)  Front of Residence:         On or about December 11, 2012              Employees were exposed to falls of 12 feet while working on the exterior masonry walls from a tubular welded frame scaffold 2 frames high which was supported on unsafe mudsills in that masonry block was improperly stacked.
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 23, 2013
Abate by
Jan 31, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.451(g)(1)(vii):     For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a)  Front of Residence:         On or about December 11, 2012              Employees were exposed to falls of 12 feet while working on the exterior masonry walls from a tubular welded frame scaffold 2 frames high.
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

View A&A Masonry INC.'s full OSHA safety record →