Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLERMONT ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CLERMONT ROOFING, INC. in 4010 KILAMONAK STREET, APOPKA, FL 32712 (NAICS 238160). OSHA activity number 337844211.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clermont Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Clermont Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4010 KILAMONAK STREET
City
APOPKA
State
FL
ZIP
32712
Mailing
802 SOUTH HIGHWAY 27, MINNEOLA, FL 34715
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Feb 13, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(13):   Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a)  On or about December 10, 2012, an employee removing shingles from a 6:12 pitched bi-level residential roof was not protected from a fall hazard of 12 feet from the eave to the ground below.    (b)  On or about December 13, 2012, two employees installing shingles on the 6:12 and 5:12 pitched sections of the bi-level residential roof were not protected from falls of 12 feet and 22 feet from the eaves to the ground below.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1053 B01

Other-than-serious 1 instance 1 exposed
Issued
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1):   Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    (a) On or about December 10, 2012, the extension ladder used by employees to gain access to the roof was not positionsed the required minimum 3 feet above the eave or landing of the roof.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337844211.