2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SUBLETTE FARMERS ELEVATOR COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUBLETTE FARMERS ELEVATOR COMPANY in 100 MAIN STREET P.O. BOX 289, SUBLETTE, IL 61367 (NAICS 424510). OSHA activity number 337845416.

Watch Sublette Farmers Elevator Company — free Get an email when a new federal OSHA severe-injury report for Sublette Farmers Elevator Company is published. One employer, no account, unsubscribe in one click.
Site address
100 MAIN STREET P.O. BOX 289
City
SUBLETTE
State
IL
ZIP
61367
Mailing
100 MAIN STREET P.O. BOX 289, SUBLETTE, IL 61367
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
10
Ownership type
A

2 citations on file for this inspection.

1910.272 J02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.272(j)(2)(ii):   The employer did not immediately remove any fugitive grain dust accumulations whenever the exceeded 1/8 inch (.32cm) at priority housekeeping areas, pursuant to the housekeeping program for grain elevators:  Fugitive grain dust had accumulated to a depth of 7/16 inch adjacent to the dump pit leg.    Abatement cerification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.272 M03

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.272(m)(3):   A certification record was not maintained of each inspection, performed in accordance with this paragraph (m), containing the date of the inspection, the name of the person who performed the inspection and the serial number, or other identifier, of the equipment specified in paragraph (m)(1)(i) of this section that was inspected.  a)  Sublett Farmers Elevator Company did not maintain inspection records of the one man electric elevator (manlift) used to gain access to upper levels.   b)  Sublett Farmers Elevator Company did not maintain equipment inspection records after September 7, 2011 . Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337845416.