On , OSHA opened a planned safety inspection of BROOKS & SONS ROOFING LLC in 180 SUMMER AVE., COLLINSVILLE, IL 62234 (NAICS 238160). OSHA activity number 337853238.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BROOKS & SONS ROOFING LLC
- Site address
- 180 SUMMER AVE.
- City
- COLLINSVILLE
- State
- IL
- ZIP
- 62234
- Mailing
- 933 GREENWOOD, MADISON, IL 62060
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B01
- Issued
- Feb 19, 2013
- Abate by
- Mar 15, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. Employees working from a 4 in 12 pitch roof were exposed to falls of approximately 10 feet 9 inches to a lower level. The employer did not initiate and maintain an accident prevention program to control and eliminate the hazards present at the jobsite in accordance with the OSHA regulations.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.20 B02
- Issued
- Feb 19, 2013
- Abate by
- Mar 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. Employees working from a 4 in 12 pitch roof were exposed to falls of approximately 10 feet 9 inches to a lower level. The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.102 A01
- Issued
- Feb 19, 2013
- Abate by
- Feb 25, 2013
- Penalty
- Initial $1,600 · Current $875 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. Employees installing shingles with a pneumatic nail gun were not wearing ANSI rated Z 87.1 eye protection. The employer failed to provide his employees with eye protection while using a pneumatic nail gun.
Recent events (2)
- — I (S) $875
- — Z (S) $1600
1926.501 B13
- Issued
- Feb 19, 2013
- Abate by
- Mar 18, 2013
- Penalty
- Initial $2,800 · Current $1,625 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. Employees working from a 4 in 12 pitch roof were exposed to falls of approximately 10 feet 9 inches to a lower level. Employees were not protected from falling by guardrail systems, safety net systems, or a personal fall arrest systems or any other approved means.
Recent events (2)
- — I (S) $1625
- — Z (S) $2800
More inspections at Brooks & Sons Roofing LLC
View Brooks & Sons Roofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337853238.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.