OSHA Inspection: FERDO REFRIGERATION EQUIPMENT, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FERDO REFRIGERATION EQUIPMENT, INC. in 429 DEVOE AVENUE, BRONX, NY 10460 (NAICS 811310). OSHA activity number 337856215.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ferdo Refrigeration Equipment, INC. — free Get an email when a new federal OSHA severe-injury report for Ferdo Refrigeration Equipment, INC. is published. One employer, no account, unsubscribe in one click.
Site address
429 DEVOE AVENUE
City
BRONX
State
NY
ZIP
10460
Mailing
429 DEVOE AVENUE, BRONX, NY 10460
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
6
Ownership type
A

9 citations on file for this inspection.

1910.107 C06

Serious Gravity 5 4 instances 6 exposed
Issued
Apr 1, 2013
Abate by
Apr 11, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined was not explosion-proof type approved for  Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    Location: Spray Room    a) Two large exhaust fans located inside the spray room were not explosion-proof type approved for Class I, group D locations.  Flammables liquids are sprayed within 20ft of the exhaust fans; on or about 12/13/12.      b) Flourescent lights located inside the spray room were not explosion-proof type approved for Class I, group D Locations.  Flammable liquids are sprayed within 20ft. of the exhaust fans; on or about 12/13/12.
Recent events (2)
  • — Z $14000
  • — Z (S) $2000

1910.107 C07

Serious Gravity 5 2 instances 6 exposed
Issued
Apr 1, 2013
Abate by
Apr 11, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not protected from mechanical injury by suitable guards or by location;      Location:  Spray Room    a) Two sets of fluorecent lights located within 20ft. of the spraying area did not have protective covers on them; on or about 12/13/12.
Recent events (1)
  • — Z (S) $2000

1910.107 C08

Serious Gravity 5 3 instances 6 exposed
Issued
Apr 1, 2013
Abate by
Apr 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c)(8):  Portable electric lamps were used in spraying area during spraying operations. Portable electric lamps, if used during cleaning or repairing operations, were not  the type approved for hazardous Class I locations.    Location: Spray room    a) Two drop lights in the spray room were not approved for Class I locations: on or about 1/28/13.
Recent events (1)
  • — Z (S) $0

1910.107 E02

Serious Gravity 5 9 instances 6 exposed
Issued
Apr 1, 2013
Abate by
Apr 15, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.107(e)(2):  The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 F (93 C) were kept in the vicinity of spraying operation. The minimum required for operations exceeded a supply for 1 day or one shift.    Location: Spray room    a) Approximately eight cans of paint and a 5-gallon container of paint thinner were stored for more than one day in the spray room; on or about 1/28/13.
Recent events (1)
  • — Z (S) $1600

1910.107 G02

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 1, 2013
Abate by
May 16, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:    Location: Spray room    a) The employer did not clean the spray area as frequently as practicable to prevent deposits of combustible residues from accumulating on walls and working surfaces; on or about 1/28/13.
Recent events (1)
  • — Z (S) $1200

1910.134 C01

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 1, 2013
Abate by
Apr 11, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use    Location: Spray Room    a) Employees are required to wear half-face negative pressure respirators when spray painting refrigerator parts.  The employer did not establish a respirator protection program; on or about 12/13/12.
Recent events (1)
  • — Z (S) $1200

1910.1200 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 1, 2013
Abate by
May 4, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:(a    Location: Workplace    a)  Employees use hazardous chemicals, such as but not limited to, xylene and petroleum ether in the process of refurbishing commercial refrigerators.  The employer did not develop or implement a written hazard communication program; on or about 12/13/12.
Recent events (2)
  • — Z $5600
  • — Z (S) $1600

1910.1200 G08

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 1, 2013
Abate by
May 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift:    Location: Workplace    a)  Employees work with hazardous chemicals such as paint thinners, paints and degreasers.  The employer did not maintain any material safety data sheets in the workplace; on or about 12/13/12.
Recent events (2)
  • — Z $5600
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 1, 2013
Abate by
May 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a)  Employees use hazardous chemicals, such as but not limited to, xylene and petroleum ether in the process of refurbishing commercial refrigerators.  The employer did not provide hazard communication training; on or about 12/13/12.
Recent events (2)
  • — Z $5600
  • — Z (S) $0

View Ferdo Refrigeration Equipment, INC.'s full OSHA safety record →