BRONX, NY —
OSHA Inspection: FERDO SUPERMARKET EQUIPMENT CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FERDO SUPERMARKET EQUIPMENT CORP. in 429 DEVOE AVE., BRONX, NY 10460 (NAICS 811310). OSHA activity number 337860217.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FERDO SUPERMARKET EQUIPMENT CORP.
- Site address
- 429 DEVOE AVE.
- City
- BRONX
- State
- NY
- ZIP
- 10460
- Mailing
- 429 DEVOE AVE., BRONX, NY 10460
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 9
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Apr 1, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Location: Establishment, Storage Room a) Storage room utilized by employer for storing refrigerator parts did not have railings to prevent employees from falling up to 9 feet to the workroom floor below on or about 12/13/13.
Recent events (2)
- — Z $15680
- — Z (S) $2800
1910.36 C01
- Issued
- Apr 1, 2013
- Abate by
- Apr 11, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.36(c)(1): Each exit discharge did not lead directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside: Location: Establishment, Rear Exit a) Rear exit discharge lead to a staircase that did not extend down to the ground, thus exposing employees to falling and egress hazards in the event of an emergency exit from the establishment on or about 12/13/12.
Recent events (2)
- — Z $11200
- — Z (S) $2000
1910.37 A03
- Issued
- Apr 1, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: Location: Establishment, Rear Exit Route a) Exit route leading outside of the rear of the establishment was obstructed by various equipment, thus impeding employees ability to exit the establishment in the event of an emergency.
Recent events (1)
- — Z (S) $0
1910.37 B02
- Issued
- Apr 1, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Location: Establishment, Rear Exit a) Rear exit of the establkishment was not marked and visible with a sign reading "exit", thus impairing employees ability to safely egress the establishment on or about 12/13/13.
Recent events (2)
- — Z $11200
- — Z (S) $0
1910.305 G02 III
- Issued
- Apr 1, 2013
- Abate by
- Apr 11, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: Location: Establishment, Spray Booth Area a) Flexible cords were used in the spray room to provide power to fans did not have strain relief, thus exposing employees to electrical arcing hazards on or about 12/13/12.
Recent events (1)
- — Z (S) $2000
1910.305 G01 IV B
- Issued
- Apr 1, 2013
- Abate by
- Apr 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible extension cords were run through holes in walls, ceilings, or floors: Location: Establishment, Outside Spray Booth a) Employees in the spray booth area were extending flexible extension cords through walls outside of the spray booth and extending the extension cord into the spray booth, on or about 12/13/12.
Recent events (2)
- — Z $11200
- — Z (S) $0
More inspections in this industry (NAICS 811310)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337860217.