JEFFERSON CITY, MO —
OSHA Inspection: DELONG'S INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DELONG'S INC in 301 DIX ROAD, JEFFERSON CITY, MO 65109 (NAICS 332312). OSHA activity number 337910012.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELONG'S INC
- Site address
- 301 DIX ROAD
- City
- JEFFERSON CITY
- State
- MO
- ZIP
- 65109
- Mailing
- 301 DIX ROAD, JEFFERSON CITY, MO 65109
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 85
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.36 H03
- Issued
- Jan 16, 2013
- Abate by
- Feb 12, 2013
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.36(h)(3): The outdoor exit route was not reasonably straight and have smooth, solid, substantially level walkways; a) On, or at dates prior to, December 12, 2012, employees on the workroom floor were exposed to fire hazard as result of an outdoor exit route which was not substantially level because a platform outside the exit door required employees to step down to the ground surface. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.179 J02 III
- Issued
- Jan 16, 2013
- Abate by
- Feb 12, 2013
- Penalty
- Initial $2,625 · Current $1,838 Reduced
General-duty citation text
1910.179(j)(2)(iii): Frequent Inspection: Monthly inspection of overhead crane load hooks, with a certification record which included the date of inspection, the signature of the person who performed the inspection and an identifier of the hook which was inspected, was not performed. (a) On, or at dates prior to, December 12, 2012, employees in the main production building were exposed to a struck by hazard from possible failure of load hooks because monthly inspections for deformities or cracks were not accomplished or documented. Abatement Note: Abatement certification is required for this item use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- — I (S) $1837.5
- — Z (S) $2625
1910.179 J02 IV
- Issued
- Jan 16, 2013
- Abate by
- Feb 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: (a) On, or at dates prior to, December 12, 2012, employees in the main production building were exposed to a struck by hazard from possible failure of hoist chains because monthly inspections for excessive wear, twists, or distorted links were not accomplished or documented. Abatement Note: Abatement certification is required for this item use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 L03 III D
- Issued
- Jan 16, 2013
- Abate by
- Feb 12, 2013
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible: 1910.179(l)(2)(iii)(d): Pendant control stations were not kept clean and/or function labels were not legible. (a) On, or at dates prior to, December 12, 2012, employees in the main production building were exposed to a struck by hazard because the buttons of the pendant of an overhead crane was not marked to identify proper function. Abatement Note: Abatement certification is required for this item use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.303 F02
- Issued
- Jan 16, 2013
- Abate by
- Feb 12, 2013
- Penalty
- Initial $1,575 · Current $1,103 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) On, or at dates prior to, December 12, 2012, employees in the job shop were exposed to a fire hazard because circuit breakers in an electrical panel were not identified. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $1102.5
- — Z (S) $1575
1910.304 F01 VIII
- Issued
- Jan 16, 2013
- Abate by
- Feb 12, 2013
- Penalty
- Initial $1,575 · Current $1,103 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(viii) Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD." (a) On, or at dates prior to, December 12, 2012, employees in the job shop were exposed to electrical hazard from possible failure of non-switch duty circuit breakers which were used as on/off switches for facility lighting. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $1102.5
- — Z (S) $1575
1910.305 D02
- Issued
- Jan 16, 2013
- Abate by
- Feb 12, 2013
- Penalty
- Initial $2,625 · Current $1,838 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. (a) On, or at dates prior to, December 12, 2012, employees in the job shop were exposed to hazard of electrocution from open areas within an electrical panel which did not provide a protection from inadvertent contact with exposed live electrical connections. Abatement Note: Abatement certification is required for this item use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose
Recent events (2)
- — I (S) $1837.5
- — Z (S) $2625
More inspections at Delong'S INC
View Delong'S INC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337910012.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.